17
7.3 Examining the filter elements
Examination of the thickness of the ceramic wall must be done with the measuring gauge
provided. As
soon as the gauge can be pushed over the ceramic, it means it has reached its
minimum thickness,
and the filter element must be replaced. In addition, elements showing signs
of cracks must also be
immediately replaced.
7.4 Troubleshooting Guide
Problem
Possibilities
Solution
Filter delivers low water quantities
Dirty filter element
Clean the filter element
Valve is closed
Open valve
Pump unit delivers too little water
Motor is not running at the max speed
Suction filter not completely covered in
water
or dirty
Optimize the suction filter.
Clean the
filter.
Suction filter positioned poorly
(e.g. in
sediment)
Optimize the suction
filter’s position.
Loss of pressure in the
filter system
Check the entire MOT-31/54 system
for
water leakage
Unsatisfactory water quality
Filter element broken
IMMEDIATELY replace the
filter
element
Filter element has hairline cracks
IMMEDIATELY replace the
filter
element
Filter element has hairline cracks
IMMEDIATELY replace the
filter
element
Contact information
Katadyn Products Inc.
Pfäffikerstrasse 37
8310 Kemptthal
Switzerland
Tel +41 44 839 21 11 | Fax +41 44 839 21 99
|
www.katadyngroup.com