background image

 

10 

 

 

  Pump Honda 

WH 20X

 

 

 

 

 

WH 20X – extremely sturdy

 

The high-pressure pumps of the WH series are outfitted with the most durable and long- lasting 
Honda G X engines. The powerful engine and especially sturdy housing enable strong water 
delivery pressures with a water capacity of up to 500 liters per minute.  

Capacity (l/min)

 

500

 

Capacity (m³/h)

 

30

 

Static suction lift

 

8  m

 

Port diameter

 

2‘

 

Motor type

 

OHV  GX 160

 

Rated output

 

3.6 kW

 

Rated  speed

 

3600 U/min

 

Tank Capacity

 

3.1 L

 

Consumption (l/h)

 

1.6

 

Measurements  (LxWxH) 

435 x 375 x 400 mm

 

Weight

 

23.5 kg

 

 
 

 

Please refer to the accompanying Honda Manual regarding the correct handling of the 
high-pressure pump WH 20X. Both this manual and the manual from Honda must be 
read and completely understood. 
 

Your safety depends on it! 

 

 

 

4.1  Setup Procedure 

 
 

Check the oil and fuel types and levels  according to the Honda Handbook. 

 

 

Connect the suction hose for untreated water to the pump 
and position the intake filter in the

 

water at the intended 

site based on the description in the operating instructions. 

 

 

 

 

 

 

 

 

 

 

 

Содержание MOT-31

Страница 1: ...Version 11 06 2020 MicrofiltrationSystem MOT 31 54 Water treatment by microfiltration with Katadyn ceramic filters...

Страница 2: ...entration 7 3 6 Installation requirements of components 8 3 7 Flow rates of the MOT 31 54 9 4 1 Setup Procedure 10 5 1 Setup Procedure 11 6 1 Brief description of the handle position of operational co...

Страница 3: ...Safety Guidelines The mobile Microfiltration System MOT 31 54 from Katadyn has been factory tested The dangers of improper use or failing to follow the operating procedures outlined in this manual ma...

Страница 4: ...s in this supplement Only when these are followed without exception can operators and others avoid the loss of life and serious injuries or avoid interference with the system s operation or other mate...

Страница 5: ...erations and maintenance instructions and improper repairs Improper use of the MOT 31 54 use not in compliance with instructions Use of repair parts not permitted by the MOT 31 54 manufacturer Operato...

Страница 6: ...filters are made from various natural raw materials of the highest quality standard As such we can attain a nominal pore size of 0 2 m with insignificant variations 3 2 Primary features of mobile micr...

Страница 7: ...elements become dirtier the flow rate also decreases accordingly Intervals between cleanings can be influenced positively with the appropriate placement of the suction hose Placing the hose directly...

Страница 8: ...er cleaning Intake position filter Static suction lift 5 meters Positioned near best water quality if possible Placement on a dry surface Filter Connection Pump inlet 2 suction hose and intake filter...

Страница 9: ...istance of the system will reduce the volume of treated water Optimal positioning of the intake hose reducing dirt intake increases the performance of the MOT 31 54 0 20 40 60 80 100 120 140 160 180 5...

Страница 10: ...6 kW Rated speed 3600 U min Tank Capacity 3 1 L Consumption l h 1 6 Measurements LxWxH 435 x 375 x 400 mm Weight 23 5 kg Please refer to the accompanying Honda Manual regarding the correct handling o...

Страница 11: ...a handheld cleaning device 5 1 Setup Procedure Take care that the filter unit is placed in a stable position and that the location surface is dry Remove the No 5 filter elements from the package and...

Страница 12: ...12 Hook up the cleaning hose to the corresponding threads The MOT 31 54 is now ready for use...

Страница 13: ...e B Cleaning Valve C Open Close 6 2 Filling Venting Check that all valves are closed Start the motor and vent the pump Turn the main valve A counter clockwise to open Open vent valve B just slightly W...

Страница 14: ...rain valve D emptying 6 5 Water Sampling Sampling must be performed by an experienced person according to DIN EN 25667 2 procedures The mobile Microfiltration System MOT 31 54 must be set in the opera...

Страница 15: ...D as soon as the filter elements are standing in water by 1 6 only Put the cleaning brush over the filter element and move it up and down 6 8 times and at the same time flush with water from the pump...

Страница 16: ...lve C Clean the filter elements and inside of the housing with the cleaning hose Close cleaning valve C Stop the Pump Open the drain valve D and empty the filter housing Close the cover and tighten th...

Страница 17: ...too little water Motor is not running at the max speed Suction filter not completely covered in water or dirty Optimize the suction filter Clean the filter Suction filter positioned poorly e g in sedi...

Страница 18: ...and Filters Product Number Description Picture 20621 SET Cleaning Hose MOT complete 20616 Cleaning Brush for Katadyn Filter elements 20335 Measurement gauge for Katadyn Filter elements 7010095 1 4 but...

Страница 19: ...t No 5 120003 120002 Cover Seal 500 x 9mm MOT 31 Cover Seal 643 x 9mm MOT 54 7010633 Suction Hose M MOT incl coupling to Pump 20615 1 Pair of Brush Segments Nylon 20619 1 Pair of Brush Segments Bronze...

Страница 20: ...20...

Отзывы: