33
•
Remove the glass splinters and the retainers.
•
Straighten the tongues in the corners of the laths.
•
Push the glass all the way into the upper lath and then into the lower one by adjusting the
glass. Centre it.
•
Push the locking springs into the lath ends and bend the tongues against the glass.
•
Attach the door to the stove.
5. Troubleshooting
If the clautron or the sauna fails to work as you think they should, go through the following
check list.
Filling the water tank coldtapwater it may sweat and drop of water.
Smoke leaks into the sauna, bad draught.
Is the chimney valve open?
Is the connecting pipe attached tightly both to the stove and the chimney?
There mustn't be any air leaks.
Is the stove’s other flue opening closed tightly with the cap that came with the stove?
Is there ash in the cludron channels?
Is the connecting pipe between stove and chimney clear of ash?
Is the chimney fully open? In need of sweeping, stuffed with snow, winter cap on etc.
Is the chimney intact? Cracks, weathered
Is the draught height (chimney height) sufficient with regard to the environment?
Nearby trees, a steep hill etc. requires more than 3.5. metres as measured from the chimney
floor.
Is the chimney’s size correct?
At least a half brick wide or, depending on stove model, a round chimney of 115 or 130 mm.
The water does not heat up properly.
Whether the cauldron been fired sufficiently.
Smoke fire according to the instructions.
Werher the chimney draft too weak.
Whether the water bottom of the tank clean.
6. Warranty and manufacturer identification
WARRANTY
Helor products are high quality and reliable. Helo Oy grants a 2 year factory warranty to its
Helo wood-burning sauna heaters covering manufacturing defects.
Damages caused by incorrect use or use which is not in accordance with instructions will not
be covered by the warranty. See chapter2.9 and 3.
MANUFACTURER
TylöHelo.
Pohjoinen Pallbontie 1.
10940 Hanko. Finland
Tel. +358207560300
www.tylohelo.com