background image

5

 

Cod. 2050-0001  Rev 1.1 

FEATURES OF THE EQUIPMENT 

 

2.1

 

RECOMMENDED USE 

EASY:FAST is equipment able to modify organoleptic and chemical characteristics of potable water, reducing 
saline content. 
It can be installed in home and in work place. 
It can be used for the production of osmotic water for commercial and HO.RE.CA applications. 
The equipment can be connected to dishwashers and coffee machines for cafés, hotels and restaurants. 

 

2.2

 

FORBIDDEN USE 

  

WARNING 

 

Use for drinking purposes: 
IT IS STRICTLY FORBIDDEN to use the equipment for the treatment of non- 
drinking water. 
IT IS STRICTLY FORBIDDEN to use the equipment in the absence of periodic 

maintenance. 
IT IS STRICTLY FORBIDDEN to use the equipment in hygienic conditions or 

environments that aren't in compliance with those indicated in this manual. 

IT IS STRICTLY FORBIDDEN to supply the equipment with waste water, sea water 
or water in chemical, physical and biological that do not meet the drinkability 
limits. (Industrial waste or chemical processing). 

The device can be used by children aged less than 8 years, and by people with 
reduced physical, sensory or mental capabilities, or lack of experience or 
knowledge, only under surveillance or after their having received instructions 

about safe use and understood of the dangers inherent in it. 

  

WARNING 

 

The company is not responsible for any damage to persons or property resulting from 
failure to follow these directions. 

Содержание EASY:FAST

Страница 1: ...1 Cod 2050 0001 Rev 1 1 EASY FAST MANUAL EQUIPMENT FOR POTABLE WATER TREATMENT...

Страница 2: ...DIRECT SUN ACTION AND FROM THE FROST MAKE SURE THAT ACCESS TO THE APPLIANCE IS ALLOWED ONLY TO QUALIFIED PERSONAL BEFORE USING THE USER HAS TO READ THIS MANUAL CAREFULLY AND TAKE NOTE OF THE WARNINGS...

Страница 3: ...INSTALLATION 9 3 2 EXCHANGE OF THE CAPILLARY 10 4 FUNCTIONING 11 4 1 FIRST START UP 11 4 2 NORMAL USE 11 4 3 MIX 11 4 4 LOW PRESSURE ALARM 11 4 5 LEAKAGE ALARM 11 4 6 INACTIVITY 11 4 7 ELECTRONIC BOA...

Страница 4: ...nly perform the operations described in this manual and they have not to perform tasks reserved to maintenance or qualified technician WARNING This equipment needs regular maintenance in order to guar...

Страница 5: ...pment in the absence of periodic maintenance IT IS STRICTLY FORBIDDEN to use the equipment in hygienic conditions or environments that aren t in compliance with those indicated in this manual IT IS ST...

Страница 6: ...able Minimum water temperature C 5 Maximum water temperature C 35 Minimum inlet capacity l h 400 Maximum inlet pressure 500 kpa Minimum inlet pressure 150 kpa LOCATION SPECIFICATIONS Maximum relative...

Страница 7: ...NNER LAYOUT 1 By pass valve and mix 2 Inlet solenoid valve 3 Maximal pressure switch 4 Minimal pressure switch 5 Permeate block 6 Membranes 7 Expansion tank 8 Expansion tank charge 9 PROFINE BLUE SMAL...

Страница 8: ...pecifications listed in the CE plate with an efficient ground and protected by 0 03 mA differential switch If the power cord is damaged it must be replaced by the manufacturer dealer or a similarly qu...

Страница 9: ...m drill bit drill a hole in the exhaust pipe of the siphon at the nut just disassembled Insert the drain pipe into the nut and tighten the nut on the bracket Tighten the nut and install the valve with...

Страница 10: ...5 BLUE 105h BLACK 95h 8 WHITE 85h 7 5 BLACK 95h 7 HARDNESS F 11 12 25 26 35 36 44 Dh 5 6 15 16 20 21 25 WARNING After replacing the capillary set the filter change time in the control unit 4 8 WARNIN...

Страница 11: ...s it with water permeate downstream of the membranes This device must be calibrated during installation Emergency BY PASS function with unplugged power supply system when it s open it lets the regular...

Страница 12: ...ssing key the software release is displayed It performs the flushing of the membranes for 2 minutes by opening the inlet solenoid valve It resets the hours of operation of the filter Confirm with It d...

Страница 13: ...the and keys and confirm with the key Select functioning by time or without time limitwith the and keys and confirm with the key Access the modification of the litres hour conversion parameter with t...

Страница 14: ...It is advisable to carry out routine maintenance at least 1 time every 6 months even if you have not reached the limit of exhaustion of the filters WARNING This equipment should be serviced periodical...

Страница 15: ...f the new cartridge in the provided space Insert the new cartridge without forcing it in any way making sure to enter the tabs in their own seats in the head and turn it 90 to the right until it stops...

Страница 16: ...smotic water or dose 250 ml of hydrogen peroxide at 24 volumes per 10 liters of osmotic water or dose 180 ml of hydrogen peroxide at 36 volumes per 10 liters of osmotic water or dose 50 ml of hydrogen...

Страница 17: ...e Reset the alarm see 4 6 If the alarm repeats or in case of water leakage close the upstream water supply valve unplug it and contact the assistance service Problem With the display turned on and wor...

Страница 18: ...in hydraulic circuit Contact assistance service Problem With dishwasher in loading phase with display on the osmosis doesn t start Cause Solution Incorrect connections The in out links were inverted M...

Страница 19: ...hazardous materials into the municipal waste stream The crossed out bin symbol reminds the user not to dispose of this product as unsorted municipal waste If disposed of privately exhausted filters a...

Страница 20: ...cribed above is in conformity with the relevant Union harmonization legislation 2006 42 UE machines 2014 30 UE EMC 2014 35 UE LVD 2011 65 UE RHOS2 References to the relevant harmonized standards used...

Страница 21: ...21 Cod 2050 0001 Rev 1 1 ATTACHMENT II MAINTENANCE LOG INSTALLATION TECHNICIAN TECHNICIAN TECHNICIAN REGULAR MAINTENANCE TECHNICIAN TECHNICIAN TECHNICIAN...

Отзывы: