manualshive.com logo in svg
background image

2400 - 4400 VFX AERATOR MANUAL

7

Correct anchoring

Providing strain relief on the cord helps ensure that 

its weight and any strain placed on it in the water will 

not cause the float to tilt or cause damage to the unit. 

If your Kasco cord comes with a strain relief kit at-

tached, attach the available link to the float-side knot 

in the mooring rope, as pictured here.

Cord Strain Relief

Use ropes to position the fountain in the desired 

location in the pond or lake. Anchor the ropes or 

secure them to the shoreline so that they are free of 

slack, but not tight. To prevent twisting of the unit 

due to motor torque, place the anchor at least 3 feet 

from the float for each foot of depth (Ex. a 6ft deep 

pond would require an anchor 18ft horizontally 

from the float).

Alternate Installation

In ponds where the water level fluctuates signifi

-

cantly, a small weight may need to be suspended at 

the midpoint of the rope to take up any slack caused 

by a drop in water level (1 foot of 1’’ galvanized pipe 

works well). The weight should be light enough so 

that the fountain can rise as the water level rises. 

This weight can also help hide the anchoring ropes 

by sinking them further below the surface.

UNIT INSTALLATION INSTRUCTIONS

After unit is installed in the water, connect the pow-

er cord to a properly installed Kasco control panel 

(C-85, C-95, etc.) with built-in ground fault protection 

according to the instructions and electrical sche-

matics included with the panel. Follow all local and 

national electrical codes for unit and control panel 

installation; consult a qualified electrician or service 

person if needed. 

Anchor rope

Secondary weight

Normal water level

Low water level

High water level

Power cord Kasco power 

control box

Incorrect anchoring

Anchoring

Back to Contents

Содержание VFX

Страница 1: ...15 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884170 Document version 2021 2 1 VFX DECORATIVE AERATOR 2400 3400 4400 30...

Страница 2: ...ABLE OF CONTENTS QUESTIONS Safety First 2 General Instructions 3 Unit Specifications Pattern Size 4 Parts Included 5 Unit Installation Instructions 7 Replacement Parts 8 Maintenance Recommendations 9...

Страница 3: ...h your control panel NEVER run the unit out of the water This will damage the seals and create a dangerous situation for the operator Use extreme caution around water especially cold water as in sprin...

Страница 4: ...balance It is extremely important to test the GFCI breaker in the control panel upon each installation re installa tion of the unit to ensure proper functioning Use Operation Kasco aerators are desig...

Страница 5: ...into C 25 3400VFX 5 5 ft 21 ft 110 120 7 3 18 C 25 plug in Plug into C 25 3400HVFX 5 5 ft 21 ft 208 240 3 7 9 Hardwire C 85 Plug into or hardwire C 85 4400VFX 8 ft 26 ft 110 120 11 3 40 C 25 plug in...

Страница 6: ...10 4 1 4 split washers 7 840537 5 1 4 3 4 OD flat washer 10 251300 6 1 4 20 x 1 3 4 hex head screw 3 475630 7 Bottom screen section 3 361540 8 1 4 20 nut 3 840536 9 8 nut 6 771034 10 8 flat washer 12...

Страница 7: ...ock washer goes between bolt and flat washer Tighten down in 4 places 3 4 5 9 10 11 12 10 3 Turn over Bring bottom screen sections together 8 4 5 5 6 ASSEMBLY INSTRUCTIONS 4 Tighten down in 6 places t...

Страница 8: ...n ponds where the water level fluctuates signifi cantly a small weight may need to be suspended at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized...

Страница 9: ...0VFX 1 240595 5B Prop 3400VFX 3400HVFX 1 340595 5C Prop 4400VFX 4400HVFX 1 440600 6A Top disk 2400VFX 1 241025 6B Top disk 3400VFX 3400HVFX 1 241035 6C Top disk 4400VFX 4400HVFX 1 241045 7 O ring 1 99...

Страница 10: ...l lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEANING Aerators should be removed from the water at least once per year at the en...

Страница 11: ...when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on...

Страница 12: ...zinc anode around the motor shaft shows significant deterioration not maintained ac cording to Recommendations supplied in this Owner s Manual Warranty Claim Procedure The best method for establishin...

Страница 13: ...re rejected for repair will be destroyed unless otherwise directed by the customer Re jected equipment can be returned at the customer s expense for shipping and handling charges Billing All non warra...

Страница 14: ...ment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by th...

Отзывы: