Inspect the Shipment

Immediately inspect your Kasco Aerator shipment for any visible damages.  Also cross-reference the parts 

supplied with the Parts Included sheet to check for shortages.  Shortages should be reported immediately to 

your Kasco Marine distributor or representative and damages reported to your carrier and Kasco Marine.

Assembly & Installation

Please see the proper Assembly and Installation Instructions enclosed in this manual.  Each is specific for 

your model and size of aerator. 
•  Use a nylon tie to help keep the power cords for the unit and lights free of the propeller by tying each 

cord to either side of the float. If you have a light kit, make sure that the unit cord is tied to one side of 

the float and the light cord to the other for balance.  

•  It is extremely important to test the GFCI breaker in the control panel upon each installation/re-installa-

tion of the unit to ensure proper functioning.

Use & Operation

Kasco aerators are designed and engineered for continuous duty, such as on fish farms or other aquacul

-

ture applications, or on-demand use, as needed in a recreational water feature. During flotation operation, 

the water is pulled from 360 degrees around the unit and from below the unit. The water is pulled upward 

and thrust through the flotation collar into the air. Your Kasco Marine aerator is ready for immediate use 

(after installation). Make sure to keep the motor housing clean from hard water deposits and/or algae. (See 

Maintenance Recommendations.) It is extremely important that proper and sufficient voltage is supplied to 

the aerator motor. Unit should be protected by a GFCI. Control panels must be installed by a qualified elec

-

trician. (See Installation instructions).

GENERAL INSTRUCTIONS

Back to Contents

Содержание VFX

Страница 1: ...15 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Operation Maintenance Manual Document number 884170 Document version 2021 2 1 VFX DECORATIVE AERATOR 2400 3400 4400 30...

Страница 2: ...ABLE OF CONTENTS QUESTIONS Safety First 2 General Instructions 3 Unit Specifications Pattern Size 4 Parts Included 5 Unit Installation Instructions 7 Replacement Parts 8 Maintenance Recommendations 9...

Страница 3: ...h your control panel NEVER run the unit out of the water This will damage the seals and create a dangerous situation for the operator Use extreme caution around water especially cold water as in sprin...

Страница 4: ...balance It is extremely important to test the GFCI breaker in the control panel upon each installation re installa tion of the unit to ensure proper functioning Use Operation Kasco aerators are desig...

Страница 5: ...into C 25 3400VFX 5 5 ft 21 ft 110 120 7 3 18 C 25 plug in Plug into C 25 3400HVFX 5 5 ft 21 ft 208 240 3 7 9 Hardwire C 85 Plug into or hardwire C 85 4400VFX 8 ft 26 ft 110 120 11 3 40 C 25 plug in...

Страница 6: ...10 4 1 4 split washers 7 840537 5 1 4 3 4 OD flat washer 10 251300 6 1 4 20 x 1 3 4 hex head screw 3 475630 7 Bottom screen section 3 361540 8 1 4 20 nut 3 840536 9 8 nut 6 771034 10 8 flat washer 12...

Страница 7: ...ock washer goes between bolt and flat washer Tighten down in 4 places 3 4 5 9 10 11 12 10 3 Turn over Bring bottom screen sections together 8 4 5 5 6 ASSEMBLY INSTRUCTIONS 4 Tighten down in 6 places t...

Страница 8: ...n ponds where the water level fluctuates signifi cantly a small weight may need to be suspended at the midpoint of the rope to take up any slack caused by a drop in water level 1 foot of 1 galvanized...

Страница 9: ...0VFX 1 240595 5B Prop 3400VFX 3400HVFX 1 340595 5C Prop 4400VFX 4400HVFX 1 440600 6A Top disk 2400VFX 1 241025 6B Top disk 3400VFX 3400HVFX 1 241035 6C Top disk 4400VFX 4400HVFX 1 241045 7 O ring 1 99...

Страница 10: ...l lubrication of seals units that sit upright for many months or years have a greater likelihood of seals drying out CLEANING Aerators should be removed from the water at least once per year at the en...

Страница 11: ...when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will continue to turn on...

Страница 12: ...zinc anode around the motor shaft shows significant deterioration not maintained ac cording to Recommendations supplied in this Owner s Manual Warranty Claim Procedure The best method for establishin...

Страница 13: ...re rejected for repair will be destroyed unless otherwise directed by the customer Re jected equipment can be returned at the customer s expense for shipping and handling charges Billing All non warra...

Страница 14: ...ment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be accompanied by th...