ROBUST-AIRE MANUAL

2

120V

IMPORTANT: PLEASE READ THIS MANUAL AND SAVE FOR FUTURE REFERENCE

•  Use caution when dealing with any electrical equipment.
•  Use caution around water.
•  Running the system in conditions below freezing may create open areas of water at the diffuser locations 

and thin ice in the surrounding area.

•  Some areas require warning signs to be posted. The system owner will assume all risks of operating the 

Robust-Aire™ system during winter months. Check your local laws and ordinances.

•  Do not use boats that tip easily, such as canoes, for installation. Follow all boating safety rules and 

regulations, including wearing a PFD (Personal Flotation Device).

•  Consult a qualified electrician for electrical installation.
•  This system requires two receptacles:

SAFETY FIRST

WARNINGS:

UNIT SPECIFICATIONS

Electrical Shock Hazard

Electrical Shock Hazard

Model

Compressor

# of  

Diffusers

Voltage/Phase

Amps

RA7

KM-120C (1/2HP, x3)

7

120V / 1

10.5

RAH7

KM-120HC (1/2HP, x3)

7

208-240V / 1

5.25

RA8

KM-120C (1/2HP, x3)

8

120V / 1

10.5

RAH8

KM-120HC (1/2HP, x3)

8

208-240V / 1

5.25

RA9

KM-120C (1/2HP, x3)

9

120V / 1

10.5

RAH9

KM-120HC (1/2HP, x3)

9

208-240V / 1

5.25

RA10

KM-120C (1/2HP, x4)

10

120V / 1

14

RAH10

KM-120HC (1/2HP, x4)

10

208-240V / 1

7

RA11

KM-120C (1/2HP, x4)

11

120V / 1

14

RAH11

KM-120HC (1/2HP, x4)

11

208-240V / 1

7

RA12

KM-120C (1/2HP, x4)

12

120V / 1

14

RAH12

KM-120HC (1/2HP, x4)

12

208-240V / 1

7

NEMA 5-15

NEMA 5-20

NEMA 6-15

240V

or

Back to Contents

Содержание Robust-Aire RA7

Страница 1: ...d Prescott WI 54021 715 262 4488 sales kascomarine com kascomarine com MOVING WATER FORWARD SINCE 1968 Installation Operation Manual Document number 774009 Document version 2022 1 0 LARGE CABINET DIFF...

Страница 2: ...Safety First 2 Unit Specifications 2 Diffuser Installation 3 large cabinet installation 4 Remote Manifold Installation 5 Suggested Tools Supplies 5 Startup Procedure 7 Winter Operation 7 Filter Mainte...

Страница 3: ...ions including wearing a PFD Personal Flotation Device Consult a qualified electrician for electrical installation This system requires two receptacles SAFETY FIRST WARNINGS UNIT SPECIFICATIONS Electr...

Страница 4: ...eone assist in feeding it from shore Cut off any excess tubing at the shore before connecting to the compressor 4 Drop the loose end of the tubing near the compressor cabinet Allow a few extra feet of...

Страница 5: ...ESOR CABINET 5052 Aluminum THIS DRAWING CONTAINS PROPRIETARY INFORMATION AND SHALL NOT BE USED REPRODUCED OR DISTRIBUTED WITHOUT THE PRIOR WRITTEN CONSENT OF KASCO MARINE INCORPORATED X 02 508 XX 010...

Страница 6: ...nuously Lakes and ponds react differently to diffused aeration so exact time frames can be difficult to predict Sunny days are preferable to cloudy days for system start up since photosynthesis will s...

Страница 7: ...op Failure to maintain clean air filter will lead to excessive heat and premature failure of the compressor Replacement air filter element part number 771018 Clean filter clear Dirty filter red Slidec...

Страница 8: ...Ensure the fan is working properly Capacitor may need replacement Please contact Kasco or your distributor if any problems persist Use the maintenance sticker on the inside of the cabinet lid to track...

Страница 9: ...e warranty coverage has been established the unit may be sent to any Kas co Authorized Repair Center for evaluation and repair Please call Kasco at 715 262 4488 prior to shipping to receive any update...

Страница 10: ...amount stated by the customer Example Please repair if total is under 150 00 before shipping charges All estimates that are rejected for repair will be destroyed unless otherwise directed by the custo...

Страница 11: ...chemical treatment or wastewater application circle one Yes No Additional notes Kasco Marine 800 Deere Road Prescott WI 54021 Attn Repairs Kasco requires that all equipment sent for repair MUST be ac...

Отзывы: