3

provide at least the same submersion to properly cool 

the ixture.  Operating the ixtures out of water will 

damage the LED and void warranty.

2. Insert the ¼” x 1-3/8” bolt into the light mounting 

bracket.  Align the bracket to the loat tab by placing 

the bolt through the light mounting hole (mounting 

bracket is on top of the loat tab) as shown in Fig. 2

Fig 2: 

 

3. Install the ¼” Flat Washer, ¼” Lock Washer and 

¼” Nut against the underside of the loat tab as shown 

in Fig. 3.  Tighten the nut until snug using the 7/16” 
wrench.

Fig 3

lat washer

lock washer

1/4” nut

4. Adjust the angle of the light as desired and tighten 
the ¼” x ½” bolts on the sides of the mounting bracket 
until snug.  For more uniform illumination, it is best to 

have all three ixtures at the same angle.

5. Repeat steps 1 through 4 for the remaining ixtures.  

Assembled light ixtures are pictured in Fig. 4.  Note 

the orientation of the lights and mounting brackets.

Fig 4

•  ¼” Stainless Steel Flat Washer (6)
•  ¼” Stainless Steel Nut (6)
•  ¼” x ½” Stainless Steel Bolt (12)
•  ¼” x 1” Stainless Steel Bolt (6)
•  Nylon Cable Ties (12)
•  Lower Float Brackets (6)
•  3/8” Stainless Steel Flat Washers (3)

TOOLS & SUPPLIES NEEDED
•  Two 7/16” wrenches (or one wrench & a 7/16” 

socket with driver)

•  Two 9/16” wrenches (or one wrench & a 9/16” 

socket with driver)

•  Wire Cutter (for trimming cable ties)

LED3S19 Assembly Instructions

For ease of assembly, make sure the Aerating Fountain 
is completely assembled.  Place the assembly upright.

Instructions for mounting LED3S19 on models:
2400VFX, 3400VFX, 3400HVFX, 3400JF, 3400HJF, 
4400VFX, 4400HVFX, 4400JF, 4400HJF

1. Install the mounting brackets to the light ixtures 

as shown using ¼” lock washers and ¼” x ½” bolts.  
Hand tighten only at this time.

Fig 1

Important Note:  Installation of the LED light ix

-

tures on the above listed aerating fountain units with 
the mounting brackets oriented as shown will ensure 

proper submersion of the light ixtures.  Each ixture 

must be partially submerged in order for lights to oper-

ate properly.  Other applications for these ixtures must 

Содержание LED6S19-150

Страница 1: ...uctions pg3 Instructions For Mounting LED6S19 pg5 Maintenance Recommendations pg5 Warranty Policy pg6 Troubleshooting Tips pg8 Replacement Parts pg9 Customer Repair Form pg10 Registration Information...

Страница 2: ...angerous situation for the operator Extreme caution should be used around water es pecially cold water as in Spring Fall and Winter which poses a hazard itself NEVER lift or drag the fountain or light...

Страница 3: ...mounting brackets Fig 4 Stainless Steel Flat Washer 6 Stainless Steel Nut 6 x Stainless Steel Bolt 12 x 1 Stainless Steel Bolt 6 Nylon Cable Ties 12 Lower Float Brackets 6 3 8 Stainless Steel Flat Was...

Страница 4: ...ts Fig 9 6 Using the cable ties tie each ixture cord to bottom leg of mounting brackets using the holes provided The will act as a strain relief and will keep the cord from being damaged by the founta...

Страница 5: ...o electrical leaks in the equipment If you have repeat consistent trips of the ground fault device the equipment should be disconnected and removed from the water The power cord should be inspected fo...

Страница 6: ...ossible for any reduction or variation in performance If a change in performance is ob served the equipment should be disconnected from power and inspected WINTER STORAGE In regions where there is sig...

Страница 7: ...restored as closely as possible to the condition in which it was received and shipped at the customer s expense for shipping and handling charges Billing All non warranty repairs will be returned to t...

Страница 8: ...the light kit in and see if it operates If the GFCI trips again then the light kit may be damaged If the GFCI does not reset with light kit unplugged then it may be defective or the photo eye is not...

Страница 9: ...1 4 20x1 2 2 2 840537 LOCK WASHER 1 4 2 3 346065 BRACKET S S LED MOUNTING 1 3 MODEL LEDxS19 xxx 19 WATT LED LIGHT FIXTURE REPLACEMENT PARTS 1 2 DO NOT ATTEMPT TO OPEN CONTACT KASCO MARINE FOR INSTRUC...

Страница 10: ...d for warranty repair Do not ship the control box with the unit for repair unless otherwise instructed Today s Date ___________________ Customer Information Name _________________ Phone Number _______...

Страница 11: ...11...

Страница 12: ..._______ Serial Ex 2101LEDS3001 ____________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ Kasco M...