4
Fig 8
9. Upon installation of the assembled unit, connect
your LED light kit to your ield installed GFCI pro
-
tected outlet and timer.
Note:
Installation of these LED light ixtures on the above
listed aerator/fountain units will ensure proper sub-
mersion of the light ixtures. Each ixture must be par
-
tially submerged in order for lights to operate properly.
Other applications for these ixtures must provide at
least the same submersion to properly cool the ixture.
Operating the ixtures out of water will damage the
LED and void warranty.
A sealing cap is provided for ield removal of one light
ixture. If a ixture fails to operate it can be removed
and the cap installed onto the waterproof connector of
the power cord. This will allow you to continue to op-
erate your light kit with two ixtures while a replace
-
ment ixture is procured.
Instructions for mounting lights on model:
8400VFX, 8400JF, 2.3VFX, 2.3JF, 3.1JF, 3.3JF,
5.1JF, 5.3JF, 5.1VFX, 5.3VFX, 7.3JF
4. Insert the 1/4” x 5” bolt into the light bracket and
extension as shown in Figure 9. Place this assembly
on the loat bracket
Fig 9
6. Adjust the angle of the light as desired and tighten
the two brass thumb screws on the sides of the ixture
until snug. Do not over tighten. It is best to have all
three ixtures at the same angle.
7. Repeat steps 1 through 4 for the remaining ixtures.
Assembled light ixtures are pictured in Figure 6. Note
the orientation of the lights.
Fig 6
8. Connect each ixture cord to the power cord’s wa
-
terproof connectors.
Make sure the orange oring is installed on the plug
side of the waterproof connector.
If any are miss-
ing, check the packaging to see if any fell off during
shipping, or an extra oring was included if there is one
missing.
Hand tighten the waterproof connectors as shown in
Figure 7. Using a cable tie, tie the light kit power cord
to the loat opposite the fountain power cord. This
will keep the cord from being damaged by the foun-
tain and balance the unit properly.
Next, cable tie each ixture cord to the loat to protect
each ixture cord as shown in Figure 8.
Fig 7
Check for orange oring