Страница 1: ...Installation Manual Kardia Standard v 103...

Страница 2: ...ommissioning 20 Water Distribution 20 Hot water heater 21 Leakage Protection 24 Ventilation 25 Design 26 Placement 26 Design of ventilation system 26 Design of vacuum system 26 Design of electrical sy...

Страница 3: ...l box adapter and sensor cable This also comes with two additional wireless sensors Up to 10 wireless sensors can be added to the same system 4 Bracket for water meter 5 Check valve 6 Expansion tank 7...

Страница 4: ...ircuit breakers 11 x 15A 1 x 25A Designed for use with external electrical meter not included Space for low voltage equipment Ventilation Balanced ventilation unit with capacity of 120 L s 432 m3 h He...

Страница 5: ...s package is located on top of the Kardia unit This package contains all the necessary materials used in the construction process mainly vacuum cleaner kit The rubber shims for adjusting the substrate...

Страница 6: ...tage labels and the cover for the bottom electrical connection 5 Customer Package This package is inside the Kardia unit and contains everything that is intended for the final customer namely vacuum h...

Страница 7: ...lation manual Kardia Standard 6 Extra Accessories Available by order See www kardia no Side cover Item nr 334161 Cover the upcoming PEX pipes from the ground to the water manifold can be ordered from...

Страница 8: ...ut so that the tube protrudes approx 10cm over finished concrete 3 The main cable for electrical supply can be installed in the top or bottom of the Kardia unit 4 PEX pipe in pipe can be installed in...

Страница 9: ...ms placed under each corner where the unit shall stand The rubber shims are attached to the outside of the installation package for easy access during assembly 80x80mm rubber shims 4x2mm green 4x3mm y...

Страница 10: ...sted with approved lifting equipment The cabinet weighs 470kg 6 Cut away all packaging from the underside of the cabinet before lowering the cabinet in place Lower the cabinet into place on the rubber...

Страница 11: ...Installation manual Kardia Standard 10 Connection Roof plate connection...

Страница 12: ...11 Connection of PEL PEX water pipes 2 Hold brass pre assembly at the correct height Then mark and cut the pipe at the correct height...

Страница 13: ...Installation manual Kardia Standard 12 Screw the Pressure Reducing Valve with the enclosed sealing ring to the brass assembly and install the pipe clamp...

Страница 14: ...nstalling the access panel Manifold The manifold is equipped with screw connection for PEX pipes There is a manifold for hot water at the bottom and cold water on top The manifolds included can be rep...

Страница 15: ...are ready for connection to the electrical cabinet A pre installed ground connection from the earthing bar to the water supply is included This electrical cabinet must be connected by an authorized el...

Страница 16: ...ted on top of the Kardia unit This cable should be connected to the wall inlets The illustration below shows how to install it correctly Installation of sliding door There must be 35mm of clearance ab...

Страница 17: ...nstallation manual Kardia Standard 16 Step 1 Insert the inner door to lower sliding rail Make sure the wheel brackets are unlocked Step 2 Hang the top part into sliding rail and lock the wheel bracket...

Страница 18: ...Slide the inner door to the far left right until it clicks to the end position Step 4 Insert the outer door to lower sliding rail Make sure wheel brackets are unlocked Step 5 Hang the top part into sl...

Страница 19: ...Installation manual Kardia Standard 18 Step 6 Lock the wheel brackets...

Страница 20: ...tep 7 Make adjustments accordingly Cleaning The cabinet should be kept clean inside and all tradespersons working on the Kardia unit should clean up after themselves to ensure a smooth connection proc...

Страница 21: ...tructions below The pressure must not exceed 6 bar To adjust water pressure if required 1 Set the outlet pressure at least 1 bar below the inlet pressure 2 Close the ball valve on the input side 3 Red...

Страница 22: ...en filled with water the power can be switched on Turn on circuit breaker Pressure doesn t reduce It s possible that membrane has hopped out of position this can happen when the pressure has been adju...

Страница 23: ...o Adjust the Temperature 1 Turn the adjustable knob 1 all the way to 2 Then turn the knob towards to the desired temperature Control Points 1 Check that all pipe connections are watertight 2 Check tha...

Страница 24: ...he safety valve by turning the knob 3 further clockwise Close all open taps Adjust the mixer valve to its original setting If the tank needs to be emptied faster the safety valve can be removed by uns...

Страница 25: ...ct 3 Hand this installation manual over to the end user 4 Enter contact details on the type plate on the product Leakage Protection Connect wireless sensors and remote control See connection instructi...

Страница 26: ...that both filters are properly installed and remove debris and construction dust from the unit 3 Turn on the unit and set the mode to Home 4 Adjust fan speed in factory settings to what is specified...

Страница 27: ...ure ample space in front of the unit for servicing at least 750mm The unit must be placed inside the house s vapor barrier Design of ventilation system The ventilation system must be designed by a qua...

Страница 28: ...op or bottom of the unit See plan drawing for dimensions A pre installed ground connection from the earthing bar to the water supply is included Design of plumbing system The plumbing systems must be...

Страница 29: ...Installation manual Kardia Standard 28 Roof Plate...

Страница 30: ...ding to NS EN15251 2007 NA 2014 TEK17 or current local standard The ventilation system should not be operated without a filter Only install filters recommended for the ventilation system The ventilati...

Страница 31: ...andard 30 Supply fan Exhaust fan 0 50 100 150 200 250 300 0 50 100 150 Static pressure Pa Airflow L s 40 47 55 60 65 70 75 82 89 100 0 50 100 150 200 250 300 0 50 100 Static pressure Pa Airflow L s 45...

Страница 32: ...31 Supply fan Exhaust fan 0 20 40 60 80 100 120 0 50 100 150 Power supply W Airflow L s 0 20 40 60 80 100 120 140 0 50 100 Power supply W Airflow L s...

Страница 33: ...Installation manual Kardia Standard 32 Electrical Wiring Diagram...

Страница 34: ...connect an external switch the unit switches to standby mode when this switch is activated 4 Boost This terminal can be used to connect an external switch the unit switches to boost mode when this swi...

Страница 35: ...en the hot water taps in the house and make sure the water flows from the tap When empty close the tap by turning it counterclockwise until the valve closes completely Expansion tank Areas of Applicat...

Страница 36: ...Airtight airproof butyl rubber binder according to EN 13831 Hydro watch for tightness control of the vessel 100 flow through Wall bracket for easy installation Leakage prevention valve Type Approval...

Страница 37: ...produced by controller The valve can be closed opened manually by pulling the dial on the blue actuator and turning it in the direction you want NB Through the small glass eye on the blue actuator mot...

Страница 38: ...troller sends three signals and the light switches to red The valve s close s Check the water tap to make sure 6 Press the RESET button on the controller The light will change to GREEN and the valve s...

Страница 39: ...wireless sensor cable must be in contact with water and the IN OUT button held for 8 12 seconds Lamp A red light will come on upon confirmed disconnection If you have unplugged a sensor you must rese...

Страница 40: ...When the power comes back on remember to push down the black dial on the front of the valve Lamp B green light on the controller lights up automatically when power returns Slide the dial on the valve...

Страница 41: ...Installation manual Kardia Standard 40 Central Vacuum Cleaner Model Air watt Mm H2O m3 h Decibel AMP Liter Size cm SE1007 700 3880 315 58 7 17 12 dia x 23 30 dia x 58...

Страница 42: ...entire house can be reached with the vacuum cleaner hose by switching from one valve to another Never place a valve on the center of the wall if there is a plaster wall Drill the holes for the valve...

Страница 43: ...Installation manual Kardia Standard 42...

Страница 44: ...43 Diagram of a home installation Different installation options...

Страница 45: ...Installation manual Kardia Standard 44 Examples of correct and incorrect installations...

Страница 46: ...45...

Страница 47: ...Installation manual Kardia Standard 46...

Страница 48: ...47 Wiring diagram...

Страница 49: ...pre installed ground connection from the earthing bar to the water supply is included An equalization connection must always be located between ground rails depending on the solution employed Cover p...

Страница 50: ...it number are attached to front plate Kardia s electrical panel is equipped with CHINT overload protection and earth fault devices Main circuit breaker 4P 40A 10kA or 3P 50A 10kA The overload protecti...

Страница 51: ...ered maintenance free Functionality test once per month Electrical lifetime 2000 cycles Mechanical lifetime 2000 cycles Ground fault circuit interrupter 2P 15A K KAR 2 MOD Chint modular circuit breake...

Страница 52: ...Switchboard 47 64 86 50 00 Email contact kardia no www kardia no...