MALFUNCTIONS AND MAINTENANCE
Version 03/2008
WATERCLEAN 1600
- 88 -
• Mount the membrane detachment facility (55/3); to do this
- Place the membrane detachment facility, spacing pins (55/1)
first, over the respective pair of pressure tubes.
- Screw both of the membrane detachment screws to the stop
nut (55/2) into the thread of the permeate nipple (54/3).
- Turn both winged nuts (55/5) evenly in a clockwise direction,
thus pulling the end caps (55/4) out of the pressure tubes.
Fig. 55
• Detach the end caps of the other pressure tubes in the same way,
observing the following pair-wise arrangement:
Fig. 56
NOTE
Both the two lower end caps (56/4 and 56/5) must
each be pulled individually using the membrane
detachment facility.