Warning

Do not screw the maintenance lock onto 
the appliance during the decalcifying.
Do not use the steam cleaner as long as 
there is decalcifying agent in the boiler.

Completely empty the descaling solu-
tion after 8 hours. A small amount of the 
solution will remain in the boiler. There-
fore, you should rinse the boiler two to 
three times with cold water to remove 
any residues of the descaler.

Completely empty the steam boiler to 
remove existing water (see fig.  ).

Allow the storage compartment for the 
mains cable to dry.

Screw the maintenance lock in using 
the extension pipe.

Fill water reservoir (see page 9).

The steam cleaner is ready to use.

Note: 

The floorcloth and the terry cloth cov-

er have been pre-washed and can be used 
immediately for working with the steam 
cleaner.

You can wash dirty floorcloths and terry 
cloth covers in the washing machine at 
60°C. Do not use a liquid softener as 
this would affect the ability of the cloths 
to pick up dirt. You may tumble dry the 
cloths.

Often, failures have simple causes and you 
can do the troubleshooting yourself using 
the following overview. If you are in doubt 
or if the failure is not listed here please con-
tact the authorized customer service.

Danger

Always disconnect the mains plug and al-
low the steam cleaner to cool down before 
performing any maintenance work.
Repair works may only be performed by the 
authorized customer service.

Descale the steam boiler.

No water in the water reservoir.

Fill the water reservoir up to the "MAX" 
marking.

No water in the steam boiler. Overheating 
protection of the pump was triggered.

Turn off the appliance. 

Fill the water reservoir

Turn on the appliance.

Water reservoir has not been inserted prop-
erly or is calcified.

Remove the water reservoir and rinse it.

Insert the water reservoir and press 
downwards until it arrests.

Steam switch is secured with the lock / 
child-proof lock.

Move the selector switch for the steam 
volume to the front.

Set the thermostat to level •••.

Rinse or decalcify the boiler of the 
steam cleaner.

During longer breaks from ironing, the 
steam in the steam line can condense.

Direct the first burst of steam at a sepa-
rate piece of cloth.

Descale the steam boiler.

Care of the accessories

Troubleshooting

Long heating-up time

Steam boiler is decalcified

No steam

Indicator lamp - "water shortage" blinks 
red and signal sounds

Indicator lamp "water shortage" glows 
red

Steam lever cannot be pressed 
anymore

Steam iron "spits out" water!

After breaks during ironing, water drops 
will come out of the steam pressure iron.

High water output

Steam boiler is decalcified

Содержание SC 4.100 CB

Страница 1: ...59645060 09 12 SC 4 100 CB Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them...

Страница 2: ...2 Quick reference...

Страница 3: ...3...

Страница 4: ...4...

Страница 5: ...ems Notes about the ingredients REACH You will find current information about the ingredients at www kaercher com REACH The scope of delivery of your appliance is il lustrated on the packaging Check t...

Страница 6: ...ation Warning The appliance may only be connected to an electrical supply which has been installed in accordance with IEC 60364 The appliance may only be connected to alternating current The voltage m...

Страница 7: ...mum operating pressure of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to steam tapping If in case of a malfunction there is no wa ter in the boiler t...

Страница 8: ...utton of the steam gun locks into place Illustration Use the extension tubes if necessary To do so connect one or both exten sion tubes to the steam gun Insert the required accessories on the free end...

Страница 9: ...ch to turn on the appliance Indicator lamp heating on is blinking green Note If there is no or not enough water in the steam boiler the water pump starts and supplies water from the reservoir into the...

Страница 10: ...r This way the floor is already cleared of dirt loose particles prior to the wet cleaning Prior to treatment with the steam cleaner always check the reaction of the textiles in an inconspicuous locati...

Страница 11: ...the terry cloth cover over the hand noz zle Especially well suited for small washa ble areas shower stalls and mirrors Suited for all washable walls and floor cov erings e g stone floors tiles and PV...

Страница 12: ...udibly Make sure that there is fresh tap water in the boiler of the steam cleaner Start up the steam cleaner according to the description Wait until the steam cleaner is ready to use All fabrics can b...

Страница 13: ...the following intervals RF reservoir fillings Note Please contact your Conservancy Board or the local water supply company to inquire about the hardness of your water Disconnect the mains plug from th...

Страница 14: ...ized customer service Danger Always disconnect the mains plug and al low the steam cleaner to cool down before performing any maintenance work Repair works may only be performed by the authorized cust...

Страница 15: ...cifications Electrical connection Voltage 220 240 V 1 50 60 Hz Protection class IPX4 Protective class I Performance data Heating output 1800 W Heating output steam iron 700 W Operating pressure max 0...

Страница 16: ...70 990 5 covers made of cotton Round brush kit 2 863 058 4 round brushes for the detail nozzle Round brush kit with brass bristles 2 863 061 Removal of especially stubborn dirt ideal for insensitive s...

Страница 17: ......

Страница 18: ...www karcher co nz www karcher com au...

Отзывы: