background image

English

 7

Caution

Make sure that the power cable or ex-
tension cables are not damaged by run-
ning over, pinching, dragging or similar. 
Protect the power cable from heat, oil, 
and sharp edges.

Never fill solvents, solvent-containing 
liquids or undiluted acids (e.g. deter-
gents, benzene, paint thinner, and ace-
tone) into the water reservoir as these 
substances affect the materials used on 
the appliance.

The appliance must not be carried dur-
ing cleaning.

The appliance must provide of a stable 
ground.

Use and store the unit only in accord-
ance with the specifications in the de-
scription and/or figure.

The steam switch must not be locked 
during the operation.

Protect the appliance from rain. Do not 
store outside.

Caution

Safety devices protect the user and must 
not be modified or bypassed.

The pressure controller keeps the boiler 
pressure during the operation as constant 
as possible. The heating is turned off if the 
maximum operating pressure of 4 bar is 
reached in the boiler and is reactivated in 
case of a pressure drop in the boiler due to 
steam tapping.

If, in case of a malfunction, there is no wa-
ter in the boiler, the temperature in the boil-
er rises. The boiler thermostat turns off the 
heating. Once the boiler is filled, normal op-
eration can continue.

The safety thermostat turns off the appli-
ance if the boiler thermostat and the pres-
sure controller fails and the appliance 
overheats in case of a malfunction. Please 
contact your local KÄRCHER customer 
service to arrange for the reset of the safety 
thermostat.

The maintenance lock acts as a pressure 
control valve at the same time. It seals the 
boiler against the steam pressure that 
builds up in the boiler. 
If the pressure controller is defect and the 
steam pressure in the boiler rises, the pres-
sure control valve, and steam is emitted 
through the maintenance lock to the out-
side. 
Please contact your local KÄRCHER cus-
tomer service before you put the appliance 
into operation again.

Safety devices

Pressure controller

Boiler thermostat

Safety thermostat

Maintenance lock

Содержание SC 4.100 CB

Страница 1: ...59645060 09 12 SC 4 100 CB Operating Instructions Before first use of the unit read these operating instructions and act in accordance with them...

Страница 2: ...2 Quick reference...

Страница 3: ...3...

Страница 4: ...4...

Страница 5: ...ems Notes about the ingredients REACH You will find current information about the ingredients at www kaercher com REACH The scope of delivery of your appliance is il lustrated on the packaging Check t...

Страница 6: ...ation Warning The appliance may only be connected to an electrical supply which has been installed in accordance with IEC 60364 The appliance may only be connected to alternating current The voltage m...

Страница 7: ...mum operating pressure of 4 bar is reached in the boiler and is reactivated in case of a pressure drop in the boiler due to steam tapping If in case of a malfunction there is no wa ter in the boiler t...

Страница 8: ...utton of the steam gun locks into place Illustration Use the extension tubes if necessary To do so connect one or both exten sion tubes to the steam gun Insert the required accessories on the free end...

Страница 9: ...ch to turn on the appliance Indicator lamp heating on is blinking green Note If there is no or not enough water in the steam boiler the water pump starts and supplies water from the reservoir into the...

Страница 10: ...r This way the floor is already cleared of dirt loose particles prior to the wet cleaning Prior to treatment with the steam cleaner always check the reaction of the textiles in an inconspicuous locati...

Страница 11: ...the terry cloth cover over the hand noz zle Especially well suited for small washa ble areas shower stalls and mirrors Suited for all washable walls and floor cov erings e g stone floors tiles and PV...

Страница 12: ...udibly Make sure that there is fresh tap water in the boiler of the steam cleaner Start up the steam cleaner according to the description Wait until the steam cleaner is ready to use All fabrics can b...

Страница 13: ...the following intervals RF reservoir fillings Note Please contact your Conservancy Board or the local water supply company to inquire about the hardness of your water Disconnect the mains plug from th...

Страница 14: ...ized customer service Danger Always disconnect the mains plug and al low the steam cleaner to cool down before performing any maintenance work Repair works may only be performed by the authorized cust...

Страница 15: ...cifications Electrical connection Voltage 220 240 V 1 50 60 Hz Protection class IPX4 Protective class I Performance data Heating output 1800 W Heating output steam iron 700 W Operating pressure max 0...

Страница 16: ...70 990 5 covers made of cotton Round brush kit 2 863 058 4 round brushes for the detail nozzle Round brush kit with brass bristles 2 863 061 Removal of especially stubborn dirt ideal for insensitive s...

Страница 17: ......

Страница 18: ...www karcher co nz www karcher com au...

Отзывы: