18
Brief instruction SB-WASH
Adjustment control circuit
board
Menue point
adjustment Option
Standard
setting
Adjust
Warm-Water
Progr. 1
warm/ cold
cold
Progr. 2
warm
Progr. 3
cold
Progr. 4
cold
Time-Base
Time-Base:
30...300 s
90 s
Wash-Time
Progr. 0
100...50%
100%
Progr. 1
60%
Progr. 2
90%
Progr. 3
70%
Progr. 4
60%
Progr. 5
60%
Coin-Amount
Channel 1:
10...200
10
Channel 2:
20
Channel 3:
40
Channel 4:
40
Channel 5:
80
Channel 6:
120
Options
Halfload
On/Off
On
Alloy wheel
Off
Data
Version
Version: x.x
Statistics
Coin
Counter
Today: Coins
Total: Coins
*)
Timer
HP-Pump
Total: hours
S001: hours
S002: hours
Timer-Pro-
grams
Progr 1: hours
Progr.2: hours
Progr.3: hours
Progr.4: hours
Progr.5: hours
Error
Message
Error: Exxx
Service
Service:
Sxxx
*) Reset coin sum- daily counter: Push the "<" and ">" for two
seconds at the same time.
Interruptions and service
announcements control
circuit board
Display
Cause
E001
Set off the motor protection switch high pressure
pump
Winding protection contact motor
E002
Fuse - F1 has triggered, circulating pump, heat fan
E003
Motor protection switch of the heater has triggered
Temperature limiter 90°C triggered
E100
Interruption control circuit
Servicecode Meaning
Intervall
S001
pump head HD-pump
250 h
S002
HD-Pump totally
500 h
Menue navigation
button
Action
OK, for 2 seconds
open the menue
<, >
change values, turn menue
OK
confirm
ESC
cancel, exit
Brief Instructions
for maintenance and
servicing
Please pay attention to the section "maintenance and serv-
ice" in the operation instructions!
DAILY
Checl high pressure hose
check brush
Check information notices in the equipment
Check the pipe line and high pressure pump for tightness
Check the content of the cleaning agent container
DAILY IF FROST
Check and if needed clean the fan heater and the anti freeze cycle
After 40 operating hours, or weekly
Check oil level of the high pressure pump
Check the oil condition of the high pressure pump (is there water
in the oil?)
Clean the brush shaft and the floaing container
EVERY 14 DAYS
Clean and service the housing of the total equipment
After 160 operating hours, or monthly
Clean the coin mechanism.
Clean the filter of the cleaning agent container
Grease the joints at the doors
AFTER 250 OPERATING HOURS OR SEMI-ANNUALLY
Check pump head (Customer Service)
BEFORE THE FROST PERIOD
Check the anti freeze equipment of its function
BEFORE THE FROST PERIOD AND DURING THE FROST
PERIOD MONTHLY
Check the freezing water amount
After 500 operating hours, or yearly
Change the oil and high pressure pump
base exchanger (optional)
Pay attention to the saltusage, check daily
Refill the salt, if the water level is above the salt
Check salt container, remove sludge
The suction jet of the salt container must be put to the grounf of
the container
The gree light at the E-equipmentboard is blinking => base ex-
changer does regenerate
PROPORTION EQUIPENT HAS TO BE DECALCIFIED RM
110 (OPTION)
Pay attenetion to the amount used of the RM110, check daily
Red light at the E-equipment board => container empty
39
EN
Содержание SB-Wash-E 10
Страница 1: ...SB Wash E 5 10 59633340 01 19 Deutsch 3 English 22...
Страница 2: ...2...
Страница 19: ...17 R ckseite Kurzanleitung 19 DE...
Страница 38: ...17 Backside brief instructions 38 EN...
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ...http www kaercher com dealersearch...