3
1 Program selection switch
2 Switch position "OFF"
3 Switch position operation without con-
ductivity monitoring, (summer opera-
tion)
4 Emergency-stop switch
5 Nameplate
6 Indicator lamp operation / set button
7 Indicator lamp - fault
8 Push button acknowledge fresh water
supply / indicator lamp fresh water sup-
ply is active.
9 Indicator lamp emptying pump basin
10 Conductivity monitoring indicator lamp
11 Shutoff valve recycled water
12 Recycling water pipe
13 Pressure reducer compressed-air con-
nection
14 Display pump pressure
15 Pre-filter
16 Connection waste water line (to the
sediment basin)
17 Waste water trap
18 Switch setting for fresh water operation
19 Switch position empty pump basin
20 Switch position operation with conduc-
tivity monitoring (option), (winter opera-
tion)
21 Hydrocyclone
Operation
Operating elements
Symbol
Colour of indicator lamp
Meaning
Function key
Green
Plant is working
SET key
Start the function selected on the pro-
gramme selector switch.
Red
Fault
--
Yellow
Fresh water supply is active
Acknowledge the message.
Fresh water supply key was active / ac-
knowledge message
Yellow
The pump basin in emptied by pump
--
Yellow
Automatic conductivity monitoring was trig-
gered
--