Align the appliance horizontally at
the installation site.
Î
Remove rinsing and strainer floor
by lifting upward.
Î
Unpack the strainer floor and place
it on the opening in the basin.
Î
Unpack the filter mat and place it on
the strainer floor with the white side
on the top.
Î
Insert the strainer into the basin.
Î
Slowly pour 80 liters of RM PC-BIO
detergent into the basin.
몇
Warning
Adding any other detergent solutions
other than RM PC-BIO can deactivate
the microbes; bio-degradation of
grease and oily dirt will be hampered.
Do not add water, solvents, cleaning
petrol, petroleum, bleaching agents or
disinfectants to the appliance.
Î
Insert the plug into the socket.
For connection values, see techni-
cal data and type plate.
The appliance needs approx. 1
hour until the water temperature
reaches approx. 38 °C.
Cleaning takes place manually via the
cleaning tools.
Î
Wear safety gloves and safety gog-
gles.
Î
Place the parts to be cleaned (max.
100 kg) on the rinsing floor.
Î
Set the "Pump ON/OFF" switch to
"1/ON".
Î
Open the shut-off valve of the de-
sired cleaning tool.
Note
It is possible to simultaneously open
multiple cleaning tools.
Î
Clean the parts.
After the cleaning:
Î
Set the "Pump ON/OFF" switch to
"0/ON".
Note
The pump automatically switches off
after 10 minutes. Briefly switch the
"Pump ON/OFF" switch off and on to
restart.
Switch off the pump after completing
the cleaning tasks; this will save un-
necessary loss of detergent due to
evaporation.
몇
Warning
If the appliance remains switched on
during a power failure, then the pump
will start as soon as power supply is re-
stored. Set the "Pump ON/OFF"
switch to "OFF/0" whenever there is a
power failure.
Î
Set the "Pump ON/OFF" switch to
"0/ON".
Note
To achieve the degradation of the mi-
crobes in the detergent liquid, the tem-
perature of the detergent liquid must
be maintained constant at approx.
38 °C. Therefore, if possible, there
should be uninterrupted power supply
to the appliance even during operation-
al breaks (such as during the night, on
the weekends or during holidays).
If there is a power failure for a longer
period of time, new microbes need to
be added to the detergent solution.
Î
Replace filter mat (see section
"Maintenance and Care/ Monthly")
Î
If there is an interruption in the pow-
er supply over several weeks, pour
an additional bottle of RM microbe
solution into the appliance.
Start up
Operation
Shutting down
Restarting