Operating Instructions
NT 611 Eco K
English
9
Dry suction
Warning!
The conversion described below
must be performed without fail
prior to dry vacuuming.
As a general rule a flat pleated
filter (6.904-206 or 6.904-190)
must be used when dry-
vacuuming.
During vacuuming it is not
permitted to ever remove the flat
pleated filter.
A membrane filter (optional
accessory 6.904-212) must be
used when vacuuming fine dust in
combination with a paper filter
bag.
A membrane filter (6.904-212) can
be used for the protection of the
flat pleated filter.
!
Unlock and remove the suction
head
!
Unscrew the union nut (1)
!
Take out wire bracket (2) and
replace by blind flange
!
Remove pump and plastic
insert from the tank
!
Fit the cap instead of the waste
disposal hose
!
Open the filter cover (1)
!
Replace the coarse-dirt filter (2)
by the flat pleated filter
Fitting the brush strip
!
Remove squeegee rubbers (1)
!
Mount brush strips (2)