English
11
DANGER
Risk of electric shock.
Prior to all work on the appliance, switch off the ap-
pliance and pull the power plug.
Push the lever of the trigger gun, the device will
switch on.
Check whether the voltage indicated on the type
plate corresponds to the voltage of the mains sup-
ply.
Check the mains connection cable for damages.
Completely open the water tap.
Appliance ventilation: Switch the appliance on with
the high-pressure hose detached and operate
(max. 2 minutes) until the water exits the high-pres-
sure connection without bubbles. Switch off appli-
ance and reconnect high-pressure hose.
Pull out the sieve in the water connection using flat-
nose pliers and clean under running water.
Clean high-pressure nozzle: Remove dirt and de-
bris from the nozzle bore, using a needle and rinse
through with water from the front.
Check water flow quantity.
Slight leakage from the appliance pump is normal.
If the leakage increases contact the authorized
customer service.
Separate the spray lance from the trigger gun and
only work with the trigger gun or use the spray
lance with pressure regulation and turn the spray
lance as far as it will go in the direction of "SOFT".
Remove filter from suction hose for detergent and
clean under running water.
Check the detergent suction hose for kinks.
The warranty terms published by the relevant sales
company are applicable in each country. We will repair
potential failures of your appliance within the warranty
period free of charge, provided that such failure is
caused by faulty material or defects in manufacturing. In
the event of a warranty claim please contact your dealer
or the nearest authorized Customer Service center.
Please submit the proof of purchase.
Addresses can be found under:
www.kaercher.com/dealersearch
Troubleshooting
Appliance is not running
Pressure does not build up in the appliance
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
Warranty
Technical specifications
K 2 Basic
K 2
Electrical connection
Voltage
220-240
1~50-60
V
Hz
Power consumption
6
A
Protection class
IP X5
Protective class
II
Mains fuse (slow-blow)
13
A
Water connection
Max. feed pressure
1,2
MPa
Max. feed temperature
40
°C
Min. feed volume
8
l/min
Performance data
Working pressure
7,4
MPa
Max. permissible pressure
11
MPa
Water flow rate
5,2
5,5 l/min
Max. flow rate
6,0
l/min
Detergent flow rate
0,3
l/min
Recoil force of the trigger gun
11
N
Values determined as per EN 60335-2-79
Hand-arm vibration value
Uncertainty K
<2,5
0,3
m/s
2
m/s
2
Sound pressure level L
pA
Uncertainty K
pA
75
3
dB(A)
dB(A)
Sound power level L
WA
+
Uncertainty K
WA
91
dB(A)
Dimensions and weights
Length
280
280 mm
Width
176
242 mm
Height
443
783 mm
Typical operating weight
4,7
5,6 kg
Subject to technical changes.
Содержание K 2.97 M
Страница 1: ... ΔϳΒήόϠ English Register your product www kaercher com welcome K2 Basic K 2 59697150 02 21 ...
Страница 3: ...3 ...
Страница 5: ...5 ...
Страница 13: ......