English
31
Î
Clean sieve in the water shortage safe
guard.
Display
Troubleshotting
Î
Replace the reed switch of the water
shortage safeguard (Customer Serv-
ice).
Î
Clean the water shortage safeguard
(Customer Service).
Display
Troubleshotting
Î
Remove leaks in the high pressure sys-
tem.
Display
Troubleshotting
– Engine overload/overheat
Î
Turn device switch on "0" and let engine
cool off for min. 5 minutes.
Î
If malfunction still occurs, have device
checked by customer service.
Figure 17
Î
Check exhaust temperature limiter; re-
duce it, if required.
Display
Troubleshotting
– This error code is displayed only for ap-
pliances with the flame monitoring at-
tachment.
– See Assembly Instructions of Flame
monitoring attachment.
Figure 2 - Pos. 8
– Engine overload/overheat
Î
Turn device switch on "0" and let engine
cool off for min. 5 minutes.
Î
If malfunction still occurs, have device
checked by customer service.
Î
No line voltage, see "Appliance is not
running".
Figure 2 - Pos. 3
– Fuel tank empty
Î
Refill.
Figure 2 - Pos. 4
– Liquid softener tank is empty, due to
technical reasons a remainder stays in
the tank.
Î
Refill.
– Electrodes in the tank are dirty
Î
Clean the electrodes.
Figure 2 - Pos. 5+6
– Detergent tank is empty.
Î
Refill.
– No power
Î
Check power connection/conduit.
– Air within the system
Vent pump:
Î
Set dosing value for detergent to "0".
Î
With open hand spray gun turn device
on and off multiple times with the device
switch.
Î
Close and open the regulating spingle
(figure 9) with open hand spray gun.
Indicator lamp "Ready for use"
turns off
Fuel indicator lamp glows
Indicator lamp liquid softener glows
Indicator lamp for detergent glows
Appliance is not running
Device is not building up pressure