32
English 5.906-434.0 Rev. 00 (12/10)
During resistance measurement, 2 values can be de-
termined.
Measurement value 1
To measure the resistance, the gauge must be con-
nected to plug contacts (as shown in the illustration).
Target value:
11 kOhm
If the resistance is significantly higher or lower, the
batteries are defective.
Measurement value 2
To measure the resistance, the gauge must be con-
nected to plug contacts (as shown in the illustration).
Target value:
7.8 kOhm at 20 °C
This value is temperature-dependent.
Note
The batteries can assume a temperature of up to 55
? during the discharge process.
5.2.2 Resistance measurement