QUICKSTART

5.964-044.0 01/11

Troubleshooting

1

A

B

C

Appliance cannot be started
A Insert battery plug. 
B Set main switch to “1”.
C Check battery; charge it, if needed

2

A

Insufficient water quantity
A Check fresh water level, refill tank if 

necessary.

B Check hoses for blockages; clean if required.
C Clean the fresh water filter.

3

A

D

B

E

C

F

Insufficient vacuum performance
A Clean the seals between dirt water reservoir 

and cover and check for tightness, replace if 
required.

B Clean the flat-fold filters at the suction 

support of the suction turbine.

C Clean the vacuum lips on the vacuum bar,

replace if required

D Check suction hose for blockages; clean if 

required.
Check the suction hose for tightness; replace 
if required.

E Check if the cover on the dirt water discharge 

hose is closed

F Check the setting of the vacuum bar.

4

A

Insufficient cleaning result

BR model

A Check the brushes for wear, replace if 

required.
If the bristles are shorter than 10 mm, the 
brushes are worn out.

BD model

A Check the brushes for wear, replace if 

required.

5

A

Brushes do not turn
A Check if foreign matters block the brushes; 

remove foreign matter if required.

Содержание BR 100/250

Страница 1: ...h to 1 C Check battery status Note The device is equipped with a safety mechanism to prevent total discharge i e when the permissi ble minimum capacity is reached then the machine can only be driven and existing lamps can be switched on In such a case the battery monitoring symbol on the control console glows red Drive the machine directly to the charging station avoid any steep gradients in the p...

Страница 2: ... water max 60 C until 15 cm below the upper edge of the tank B Pour in detergent Close the cover of the fresh water reservoir Operation 1 A B Turning on the Appliance Danger Danger of accident The immobilizing brake must always be checked first on an even surface before starting the machine A Sit on the driver s seat B Set main switch to 1 2 A B E C D Drive the machine A Set programme switch to st...

Страница 3: ...d 7 A Scrub the floor without applying water vacuum polishing A Polish the floor without applying any fluid and suck in the polishing dust 8 A Manual cleaning A Apply liquid detergent using the wall ceiling floor nozzle optional and vacuum it again 9 A Info button Use the Info button to select the menu items and do the settings A Turning the button to the right left scrolls through the menus forwa...

Страница 4: ...er treatment A Take the fresh water drain hose or the dirt water drain hose from the support and lower it into a suitable collection device B Let off water by opening the dosage device at the discharge hose C Unscrew the cover of the cleaning opening of the dirt water tank Then rinse the dirt water tank with clear water 3 A B Turn off the appliance A Set programme switch to step 1 driving B Turn k...

Страница 5: ...l provisions regarding the wastewater treatment A Take the dirt water discharge hose from the support and lower above a suited collection device B Let off water by opening the dos age device at the discharge hose C Unscrew the cover of the cleaning opening of the dirt water tank Then rinse the dirt water tank with clear water 4 A B A Clean the vacuum lips and the wip ing lips check for wear and re...

Страница 6: ...aked in mild detergent 7 A A Check battery pole for oxidation brush it if required and lubricate it using pole grease Ensure that the connection cable sits firmly Check the acid density of the cells if the batteries are not mainte nance free batteries 8 A A Clean the seals between dirt water reservoir and cover and check for tightness replace if required 9 A A Have the prescribed inspection carrie...

Страница 7: ...ed B Clean the flat fold filters at the suction support of the suction turbine C Clean the vacuum lips on the vacuum bar replace if required D Check suction hose for blockages clean if required Check the suction hose for tightness replace if required E Check if the cover on the dirt water discharge hose is closed F Check the setting of the vacuum bar 4 A Insufficient cleaning result BR model A Che...

Страница 8: ... till the text on the display has disap peared Bring the key switch back to 1 switch on the machine Carry out the troubleshooting measures in the given sequence only if the fault occurs again At such times always bring the main switch to the 0 position and ensure that the emergency stop button is depressed If the fault cannot be repaired call customer service and mention the fault code s H1 022 in...