English
11
5. Store the device in a frost-protected place.
Special accessories
You will find the possible special accessories on the last
page of these operating instructions.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Specifications
Note
Reason for exception according to regulation (EU)
2019/1781 Annex I Section 2 (12): (j)
Subject to technical modifications!
Fault
Cause
Rectification
Pump is running, but not
delivering
Air is in the pump.
1. Check for correct startup (see chapter
and
Dirt particles block the suction area.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The suction hose or the connection
adapter is not correctly screwed in.
1. Check that the seals are fitted correctly.
2. Manually tighten the suction hose and con-
nection adapter.
The pre-filter is clogged.
1. Clean the pre-filter.
The pump does not start
up, or stops suddenly
during operation
The power supply is disconnected.
1. Check the fuses and the electrical connec-
tions.
The pump capacity drops
or is too low
The suction area is clogged.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
The delivery rate of the pump depends
on the delivery head and the connected
periphery.
1. Observe the max. delivery head (see chap-
ter
), select a different hose
diameter or a different hose length if nec-
essary.
The cross-section on the pressure side is
narrowed, e.g. due to the valve/ball tap
not being fully open.
1. Open the valve/ball tap completely.
The hose is kinked on the pressure side. 1. Eliminate the kink points in the hose.
The pre-filter is clogged.
1. Clean the pre-filter.
BP 4.500
Garden
BP 4.500
Garden Set
Plus
BP 5.000
Garden
BP 5.000
Garden Set
Plus
BP 6.000
Garden
BP 6.000
Garden Set
Plus
BP 7.000
Garden
Mains voltage
V
230-240
230-240
230-240
230-240
Power frequency
Hz
50
50
50
50
Nominal power
W
550
650
1000
1100
Maximum flow rate
l/h
4500
5000
6000
7000
Suction height (max.)
m
8
8
8
8
Pressure (max.)
MPa (bar) 0,36 (3,6)
0,40 (4,0)
0,45 (4,5)
0,5 (5,0)
Delivery height (max.)
m
35
40
45
50
Delivery temperature (max.)
°C
35,0
35,0
35,0
35,0
Particle size (max.) of permissible feed fluids mm
1
1
1
1
Pump type
Jet
Jet
Jet
Jet
Sound pressure level L
pA
dB(A)
56
58
69
68
Guaranteed sound power level L
WA
dB(A)
71
73
84
83
Dimensions and weights
Weight (without accessories)
kg
6,4
7,0
9,7
10,0
Содержание BP 4.500 Garden
Страница 2: ...A...
Страница 3: ...B C D E F G H I...
Страница 50: ...51 14 3 5 m 15 1 2 20 m 16 Plus Plus K rcher B C D E F 1 2 ON OFF 3 1 m I 4 5 1 OFF 2 1 2 1 1 1 2 3 4 H 5...
Страница 59: ...60 1 1 1 2 3 4 H 5 1 1 2 1 2 1 1 1 2 1 1 1 1...
Страница 96: ...97 5 1 2 1 2 1 1 1 2 3 4 H 5 1 1 2 1 2 1 1...
Страница 112: ...113 11 Aqua Stop 12 13 14 3 5 15 1 2 20 16 Set Set Plus Set Plus K rcher B C D E F 1 2 3 1 I 4 5 1 2 1 2 1 1 1 2 3...
Страница 116: ...117 8 9 10 G 1 11 12 13 14 3 5 m 15 1 2 20 m 16 B C D E F 1 2 ON OFF 3 1 m I 4 5 1 ON OFF 2 1 2 1 1 1 2 3 4 H 5...
Страница 120: ...121 12 13 14 3 5 15 1 2 20 16 Set Set Plus Set Plus rcher B C D E F 1 2 3 1 I 4 5 1 2 1 2 1 1 1 2 3 4 H 5...
Страница 123: ...127...
Страница 127: ......