34
Maintenance
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No power to machine
Battery disconnected
Check all battery cable connections;
replace or tighten as necessary.
Emergency shut-off activated
Reset
Faulty key switch
Replace switch
Battery cables corroded
Clean connections
On board charger plugged in
Unplug and stow cord
Main circuit breaker tripped
Reset circuit breaker
Little or no propel
Low battery charge
Charge batteries
Tripped circuit breaker
Reset circuit breaker and check brushes
Controller overheated
Allow cool down period
Loose motor connection
Check wires and connections from
controller to motor, replace or tighten as
necessary.
Faulty throttle circuit or potentiometer
Check wires and connections from throttle
to controller and potentiometer resistance,
replace or tighten as necessary.
Faulty platform circuit or switch
Check wires, connections and switch,
replace or tighten as necessary.
Machine does not
change speeds
Faulty speed control circuit or switch
Check wires, connections and switch,
replace or tighten as necessary.
Vacuum motor does not
run, or runs slowly
Faulty vacuum circuit or switch
Check wires connections and motor,
replace or tighten as necessary.
Worn vacuum motor brushes
Replace brushes, check commutator
Full vacuum bag
Replace vacuum bag
Clog in vacuum system
Check for and remove debris
Low battery charge
Charge battery
Poor vacuum
performance
Vacuum hose not fully connected to
brush deck or vacuum box inlet.
Check for full connection of vacuum hose at
brush deck and vacuum box inlet. Hose cuff
should be inserted so shoulder is touching
connection all around.
Debris caught in system
Remove debris
Low battery charge
Charge batteries
Brush motors do not
run, or run slowly
Low battery charge
Charge battery
Worn brush motor brushes
Replace brushes, check commutator
Faulty brush circuit or motor
Check wires, connections and motor,
replace or tighten as necessary.
Poor brushing perfor-
mance
Debris caught in brushes
Remove debris
Worn brushes
Replace brushes
Low battery charge
Charge batteries
Brush deck goes down,
then raises
Faulty actuator circuit or actuator
Check wire connections and actuator,
replace or tighten as necessary.
Debris tray needs to be
emptied too frequently
Excessive amounts of large or heavy
material on floor.
Remove debris tray insert
New carpet
Remove debris tray insert
8.644-976.0 Manual Operator CV601 RS KIRA Autonomous