Karassn KS-858G Скачать руководство пользователя страница 3

  

1.Alarm host                                 1pc               2.Key                                               2pcs

  3.Remote controller                     2pcs             4.Radio antenna                             1pc

  5.GSM antenna                             1pc               6. Double-end telephone line       1pc

  7.

2.2KΩline end Resistance       

8pcs             8. Screw                                           2pcs

  9.Self tapping Screw                    3pcs           10. Plastic Bolt                                 3pcs       

11.User's Manual                            1pc             12. Power lead                                  1pc           

The list of standard full kit

1.

Introduction

This is a Telephone&GSM/GPRS dual networking Alarm system with LCD display and 4*4 keyboard, and 
there are 16 zones (8 wireless zones and 8 wired zones). It works perfectly with remote controllers (up to 8 
remote controllers), various wireless/wired detectors, door sensor, manual call point, and wireless/wired 
sirens.  And  they  make  up  a  complete  safeguard  system  to  guard  against  theft,  fire  and  gas  leakage, 
emergency alarm and so on. This alarm host can be stored up to 5 groups of pre-set telephone numbers 
(fixed/mobile  telephone  number).  Once  alarm  happens,  the  alarm  host  will  activate  siren  to  make  alarm 
sound immediately, and dial pre-set telephone numbers at the same time, two-way audio after alarm can 
be  achieved  through  the  optional  GSM&GPRS  module;  mobile  APP  receives  alarm  information,  remote 
control and programming supported; central monitor software receives alarm information, remote control 
and  programming  supported  too.  It  is  widely  used  in  residence,  marketplace,  finance  system  and 
enterprise.

2. Main Functions:

2.1 Support two-way audio.

2.2 Support mobile APP remote control and programming, inquire record. Support central monitor software.

2.3 It is easy to operate with 4*4 keyboard and lattice LCD display.

2.4 Voice pre-recorded, it guides to operate by sound and correctly reports alarm information when alarming.

2.5 There are 8-wired zones and 8 wireless zones altogether, and they share with the zone number.

2.6 8 sub zones can be programmed independently. And the zone list can be set freely in each sub zone, 8 r

      emote controllers and 8 user's codes can separately program for 8 sub zones to ARM/DISARM

       independently.

2.7 Code classification, 1 installer code, 1 master code, and 8 common user 's codes. Add number 1 at the 

      end of master code/ common user's code, and then it will become duress code.

2.8 Support to ADEMCO CONTACT ID communication protocol

2.9 5 groups of telephone numbers (mobile and pager number) can be set. Dialing type (tone or pulse) and 

      appointed communication zone can be programmed. Arm/disarm, whether to report the information of 

      system state can be set freely.

2.10  It rushes to report alarm information when alarming (the line should be correctly connected)

2.11  Telephone line cut off or short-circuit will send an alarm. (Indicate sound or siren are optional)

2.12  Dial the telephone number, which connected with alarm host to arm/disarm and start alarm on the spot 

          function remotely through telephone or mobile phone.

2.13  Automatically learn code between Wireless PIR detector, remote controller and alarm host (each zone 

          can be learned up to 3 detectors, so it can be learned up to 24 detectors and 8 remote controllers 

          altogether).

2.14  Wired zone respond speed is 50ms-750ms, and the circuit types (Normal Open, Normal Close and 

          Line-end resistance) can be set freely to connect with all kinds of wired detector.

2.15  Two timers can be set to Arm/Disarm different zones independently.

2.16   Alarm delay time (00-99 seconds) and Arm delay time (00-99 seconds) can be set for appointed zones.

2.17  It has completed self-check function, alarm host/detector disassembly, AC power cut, backup battery 

         lower of  alarm host and detector will activate alarming.

-1-

Содержание KS-858G

Страница 1: ...PSTN GSM GPRS Alarm System User Manual 1 2 3 4 5 6 7 8 9 0 RUN AC PWR ARM EMC Z1 Z2 Z3 Z4 Z5 Z6 27 Z8 ARM SEY OK RESET WELCOME...

Страница 2: ...1 Directive 35 Set linkage alarm duration for appointed zones 12 Directive 36 Set the first group of Arm Disarm timer for zone list 12 Directive 37 Set the second group of Arm Disarm timer for zone li...

Страница 3: ...re 8 wired zones and 8 wireless zones altogether and they share with the zone number 2 6 8 sub zones can be programmed independently And the zone list can be set freely in each sub zone 8 r emote cont...

Страница 4: ...24 hours or more in standby time And it reports when power lower to avoid battery damaging it adopts limited current discharge protection circuit 2 22 Remote control arm and disarm linkage active sire...

Страница 5: ...nearby it also should be near to telephone line and within the detector defense zone Siren or trumpet should be set in the best place Emergency button should be set in the most convince place When in...

Страница 6: ...e inserted is too long If more than two lines should be connected to the same end then the bared line should be twisted firmly then insert them into the hole After that screw the screw cap firmly to b...

Страница 7: ...in some zones NC is normal close end And NO is normal open end COM is common end Their interfaces can connect with 1A120V AC 24V DC If the power of being controlled equipment over interface loads the...

Страница 8: ...nt cap opening short circuit end should be put to outer case concatenate both ani tamper switches and then connect the line end with TAMPER C interface 4 3 System Debugging Firstly check if all lines...

Страница 9: ...press Reset key then enter wanted directives 5 2 Program Instruction Enter program state Panel is in standby state or repeatedly press Reset key to set panel in standby state Press SET key the panel...

Страница 10: ...r instance you want to delete the 8th user code In installer or master program state Press 08 OK OK Note 3 1 8 user s codes and 1 8 remote controllers are defined to be 1 8 users and different users c...

Страница 11: ...rmed Disarmed and panel malfunction inspection report it will dial the second alarm phone number automatically In installer program state Press 16 OK 2 4 6 8 9 SET 0 OK LCD display will show as below...

Страница 12: ...tate Press 30 OK xxxxxxxx OK x is zone attribute of each zone 8 x is for 8 zones X value scale you can see attribute table below Note 1 Zone attribute depends on detector types 2 Fire alarm Gas alarm...

Страница 13: ...s by default Directive 33 Set Alarm delay Arm delay for appointed zones In installer program state Press 33 OK Alarm delay time Arm delay time appointed zones 1 8 OK Alarm delay time range 00 99 secon...

Страница 14: ...alarms Linkage alarm siren duration is 30 minutes In install program state press 35 OK 30 2 4 6 8 9 OK The screen will show as below Picture 14 Linkage alarm duration 20 minutes for all zones by defa...

Страница 15: ...tition Press 44 OK appointed zone no OK for the 4th partition Press 45 OK appointed zone no OK for the 5th partition Press 46 OK appointed zone no OK for the 6th partition Press 47 OK appointed zone n...

Страница 16: ...3 Enable disable bypass reporting function In installer program state Press 53 OK x OK x 0 1 0 means disable bypass reporting function 1 means enable bypass reporting function and bypass recovery repo...

Страница 17: ...host will recognize automatically to see if this code has been learned if this remote controller has been learned then the alarm host will refuse to learn this code and it will make a Di sound 1 Afte...

Страница 18: ...he 2nd sensor Press 3 OK OK to delete the 3rd sensor Press 72 OK to enter the 2nd zone register Press 1 OK OK to delete the 1st sensor Press 2 OK OK to delete the 2nd sensor Press 3 OK OK to delete th...

Страница 19: ...2345678 35 2012345678 36 Set the 1st timer for Arm Disarm No 37 Set 2nd timer for Arm Disarm No 38 Correct Date and Time 41 12345678 42 12345678 43 12345678 44 12345678 alarm Set delete the 1st alarm...

Страница 20: ...disable GPRS 1 57 Set and query IP address of master server 58 Set and query the master server port number 9022 59 Set and query heartbreak time 55 seconds 60 Register delete remote controller No 69 D...

Страница 21: ...ion or failure Slow flashing GSM initialization succeeded but network server was not logged in Indicator on Successful login to the network server Arm indicator the indicator is on for arm and off for...

Страница 22: ...ck to normal TEL Error Telephone line failure TEL Back Telephone line come back to normal MBAT Low Alarm host battery power low MBAT Back alarm host battery come back to normal TEL ErZx Low x 1 8 Zx F...

Страница 23: ...but the system also send out the alarm information through telephone to ask for help at the same time 6 3 Arm Disarm 1 The remote controller programmed to arm disarm for different partitions Press ke...

Страница 24: ...bute in Intrude Alarm or Perimeter alarm they won t activate until alarm host in Arm state So don t forget to ARM the alarm system before you leave the place 2 Emergency Alarm Press key for emergency...

Страница 25: ...d then hang up One sound indicator Du means the code is correct Then you are able to enter directive you wanted If no operation beyond 30 seconds the phone will be hung up If incorrect code was entere...

Страница 26: ...nection function enabled directive 56 enabled by default 7 1 The alarm host installs the SIM card correctly 7 2 Download APP as below 7 3 Open the APP to register an account It can be registered by em...

Страница 27: ...sfully 7 5 Alarm host operation instructions Modifiable host name Share device to other APP account Indicate online offline Away arm System settings of alarm host Note Each alarm host can only be adde...

Страница 28: ...and alarm host in open area 400m Working Environment Temperature 0 55 Humidity 10 80 8 2 Wireless Remote Controller Voltage 12V 27A Standby Current 5uA Emit Power 10mw Emit Frequency 433 92MHz 9 Opera...

Страница 29: ...alarm when powered on or Armed 1 The wired sensor connected is incorrect or connect badly Check the power cable to see if the plus terminal and signal terminal are connected correctly Or see if termin...

Страница 30: ...ed environment temperature when the temperature of protected area reach to 32 40 the performance of infrared detector detect distance will reduce So we suggest you to check its working performance car...

Страница 31: ...V1 0 P M...

Отзывы: