![Kapat KARAT-520 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/kapat/karat-520/karat-520_operation-manual_653101036.webp)
2.3.4.3. Use of SAE
It is recommenced to use sets of attachment elements during
flowmeters mounting on pipelines. SAE comprises:
n
SAE 1
consists of 2 straight sections with the length of 5ND and
3ND (pipes are in accordance with GOST 8732 (“Seamless hot-
deformed steel pipes. Range of sizes”) or GOST 8734 (“Seamless
steel tubes cold deformed. Range of sizes”)), 2 screwed caps and 2
sealing gaskets.
n
SAE 2
consists of 2 attachment flanges (in accordance with GOST
12820 (“Steel plane welded flanges for Pnom from 0,1 to 2,5 MPa
2
(from 1 to 25 kgf/cm )
Design and dimensions”) or GOST 121821 (“Electrical wires and ca-
bles in general”)), hardware kit (bolts in accordance with GOST 7798
(“Hexagon bolts, product grade B. Construction and dimensions”),
screws in accordance with GOST 9515 (“Piston metal rings for piston
compressors. Specifications”)).
SAE 2 is used both for KARAT-520-50, -65, -80 flowmeters mounting
on the pipeline with no cutting-in of straight pipes and for independent
assembling of straight sections (for the latter case it is recommended
to use pipes in accordance with GOST 8732, GOST 8734, GOST
3262 (“Water-supply and gas-supply steel pipes”)).
Ready-mounted straight section is a metal pipe with the length of not
less than 3, 5 or 10 ND. There is a mounting element (nipple or flange)
on the one end of the straight section and the other end is prepared for
welding.
Assembling of welding joints and dimensions of welding seams
should meet the requirements of GOST 16037 (“Welded joints in steel
pipelines. Main types, design elements and dimensions”). Parallel
misalignment along straight pipe should be not more than 2 mm for
200 mm length. Inner diameter of pipe used for independent assem-
bling of straight sections should meet the requirements mentioned in
table 2.2. Straight pipes appearance is given on figures 2.6 and 2.7.
Figure 2.6 –
Straight pipes for KARAT-520-50, -65, -80
50° ± 5°
1
4
ø
18
4
holes
3
, 5
, 10
ND
ND
ND
ND
В
GOST
16037-80-У7
GOST 16037-80-У7
// 2/200 А
_
0,4 В
3
, 5
ND
ND
G
Figure 2. –
Straight pipes for KARAT-520
7
-20, -25, -35, -40
СМАФ.407251.002 РЭ – Operations manual
Edition 3.0. August 2012
36
КАRАТ-520
Ultrasonic flowmeters
КАRАТ RPA
www.karat-npo.ru
ND
Содержание KARAT-520
Страница 1: ...OPERATIONS MANUAL Ultrasonic flowmeters KARAT 520 ...
Страница 2: ...Ultrasonic flowmeters KARAT 520 ...
Страница 51: ......