KPC-9612 Version 5.2 July 19, 1994
19
AXHang n (
n = 0 – 255)
{0/0}
When operating through a voice repeater this command should be set to the hang time of the re-
peater. If the TNG has detected activity within this time interval, it will not use the AXDELAY set-
ting since the repeater should still be transmitting. Each unit represents 10 milliseconds.
Beacon [Every | After]
n (n = 0 – 255)
{EVERY 0/EVERY 0}
When set to EVERY, a beacon packet will be transmitted every
n minutes. When set to AFTER, a
beacon packet will be transmitted ONCE after
n minutes of no channel activity. Setting n to 0 will
disable beacon transmissions.
See also: btext, unproto
BKondel ON|OFF
{ON}
When ON, the KPC-9612 will echo a back space-space-back space sequence to your terminal when
the DELETE character is received from the terminal. When OFF, the KPC-9612 echoes a backslash
(\) character when the DELETE character is received.
BP96 ON|OFF
{OFF}
When OFF, the 9600 baud transmit waveform filter provides the best eye pattern on the transmit-
ted signal. The transmitted bandwidth is slightly wider than a G3RUH modem. When ON, the
transmitted bandwidth is slightly narrower than the G3RUH modem, and the transmitted eye pat-
tern is slightly distorted, but will work with most radios.
BText
text (up to 128 characters)
{blank}
Specifies the contents of a BEACON packet. To clear the BTEXT, enter a single % character (BTEXT
%).
See also: beacon
BUDCalls [+|-]callsign(s)|NONE
{NONE}
A list of up to 10 callsigns for use with BUDLIST or CONLIST. To delete or add individual entries,
precede the callsign with a "-" or "+" respectively.
See also: budlist, conlist
BUdlist OFF|TO|FROM|ON
{OFF/OFF}
When OFF, all packets are eligible to be displayed as monitored packets. When ON, only those
packets TO or FROM stations listed in the BUDCALLS will be monitored When TO, only those pack-
ets addressed TO stations in the BUDCALLS will be monitored, and when FROM, only those pack-
ets FROM stations listed in BUDCALLS will be monitored.
See also: budcalls, monitor, suplist
Содержание KPC-9612
Страница 1: ...KPC 9612 Getting Started and Reference Manual...
Страница 10: ...KPC 9612 Version 5 2 July 19 1994 10...
Страница 11: ...KPC 9612 Version 5 2 July 19 1994 11...
Страница 12: ...KPC 9612 Version 5 2 July 19 1994 12...
Страница 74: ...KPC 9612 Version 5 2 July 19 1994 74 KPC 9612 Parts Layout...
Страница 75: ...KPC 9612 Version 5 2 July 19 1994 75...