9
BURR ALIGNMENT
Calibration
After assembling the main enclosure, the burrsets may need further calibration to prevent excess rubbing and
misalignment during grinding.
Using the provided hex key, tighten or loosen the three black enclosure screws until the outer burr and the inner
burr are flush with each other. Tightening a screw will decrease the gap on that side and loosening a screw will
increase it. Twist the adjustment ring during calibration to lower or raise the burrs and check burr alignment.