Temp. warning

Hot-air generator is stopped or become blow operation when outlet and inlet temp. exceeded the upper limit,
each sensor becomes the burnout by snapping of a wire etc., or the inside temp. of the hot-air generator
became warning too.
When the outlet temp. exceeded the upper limit

TEMP. WARN. lamp (Red) is lighted and "nFb" is
flickered to HOT-AIR TEMP., "TcA" to SETTING
TEMP. And, the breaker (NFB) of this machine does
trip and all the operation stop.

Main cause

Outlet temp. exceeded the upper limit at the time
of using the external sensor

Decrease of the air volume by the excessive pressure loss

Decrease of the air volume by the clogging of the
inlet filter

Return method

Please remove the cause of the outlet temp.
upper limit over. And , source power supply and
the breaker of this machine are turned OFF at
first and are turned ON again after cooling
sufficiently.  (TSK-18 is only input of the factory
power supply.)

When the inlet temp. exceeded the upper limit

TEMP. WARN. lamp (Red) is lighted and present
temp. is lighted to HOT-AIR TEMP., "Tcc" is
flickered to SETTING TEMP. And, It becomes blow
operation condition.

Main cause

When hot-air circulation temp. exceeded the
upper limit of the suction gas temp. of the hot-air
generator

Return method

Please disarm by pushing STOP switch after the
temp. of the inlet dropped.

At the time of the burnout of the outlet sensor

TEMP. WARN. lamp (Red) is lighted and "---" is
flickered to HOT-AIR TEMP., "TcA" to SETTING
TEMP.. And, the breaker (NFB) of this machine does
trip and all the operation stop.

Main cause

Snapping of a wire of the outlet sensor
Snapping of a wire of the outlet sensor wiring
Miss of the outlet sensor wiring connector

Return method

Please order the repair after turning OFF the
first power supply.

Attention : Please block the source power supply (factory power supply) without fail when the
wiring is confirmed and readjusted at the time of abnormal.

-10-

Содержание TSK-102

Страница 1: ...anges this operation manual without taking our permission TSK 122 132 TSK 92 102 Operation manual Total edition Please read without fail before use Thank you very much for purchasing Hot air generator this time Please confirm the model type and voltage by the name plate of this machine 7 Service terminal 8 Warning detection TSK 82 TSK 62 72 TSK 56 TSK 52HT TSK 42 52 TSK 23 33 Guarantee TSK 18 TSK ...

Страница 2: ...that was enclosed to the outlet and inlet Input terminal A1 A10 and output terminal B8 B10 is malfunctioned by the voltage is applied And output terminal B1 B7 is malfunctioned by the voltage more than the rating is applied Please do not unite or wire that was adjoined the wiring of the service terminal with the power supply line high tone wave line Electron devices of the inside are damaged by no...

Страница 3: ...repare separately Recommendation cord Cab tire cable 100mm 2 Please use the commercial power supply 50 60Hz that has the sine wave like to the power supply of the hot air generator Please do not use the power supply that has the distortion wave including a high tone wave from the frequency transformation device absolutely Please establish the exclusive use circuit Please decide the capacity of the...

Страница 4: ...s by the temp of storage atmosphere drops in the winter season Hot air generator becomes freezing condition if this machine is stored in the condition that the condensation occurred and it becomes the cause of the malfunction of an electricity part Individual inspection I recommend that is carried out the individual inspection in the case that the use period exceeded 10 years to have this machine ...

Страница 5: ...N switch This is lighted when the operation condition was changed to the external sensor Hot air generator is operated with the external operation signal and external heater ON OFF signal by the switch is continued to push about 2 seconds OVERHEAT lamp This is lighted and the breaker NFB is become trip in the case that the heater case inside became a abnormal high temp HOT AIR TEMP display Outlet ...

Страница 6: ...ocouple JISK Heatproof blower Hot air circulation type Breaker NFB Control panel Service terminal Eye bolt Hot air outlet Outlet temp sensor Thermocouple JISK Heatproof blower Hot air circulation type with demi filte Power cord Breaker NFB Control panel Service terminal Caster ...

Страница 7: ... and external heater input terminal E H is less than DC12V 3 6mA Please prepare the relay that has the contact capacity that can open and close this voltage Please change the external operation mode by pushing the EXT RUN switch of this machine in the case that the external operation input and external heater input is used Output terminal Contact capacity is more than DC5V 10mA less than DC30V 1A ...

Страница 8: ... case that the remote controller of the option is used For communication of the remote Please input DC4 20mA only TSK 122 and 132 4mA Heater output 0 20mA Heater output 100 Output terminal M3 20P The Lower berth of the terminal Tightening torque 0 5N m B1 Blow output terminal Contact capacity is more than DC5V 10mA less than DC30V 1A Output common terminal total is less than 3A Unvoltage point of ...

Страница 9: ...p detection OFF OFF OFF OFF OFF OFF External sensor burnout OFF TSK 52HT 62 72 82 92 102 122 132 Action of the hot air generator Blow output Hot air output Temp warning Temp alarm Blower warning Overheat output terminal terminal output terminal output terminal output terminal terminal B1 B2 B3 B4 B5 B6 OFF OFF Usually stop OFF OFF OFF OFF OFF ON OFF OFF OFF OFF Blow operation ON OFF OFF OFF OFF Co...

Страница 10: ...f this machine are turned OFF at first and are turned ON again after cooling sufficiently TSK 18 is only input of the factory power supply At the time of overheat sensor burnout Overheat lamp Red are flickered and is flickered to HOT AIR TEMP Tcb to SETTING Main cause Snapping of a wire of the overheat sensor Snapping of a wire of overheat sensor wiring Miss of the overheat sensor wiring connector...

Страница 11: ...ter cooling sufficiently TSK 18 is only input of the factory power supply When the inlet temp exceeded the upper limit TEMP WARN lamp Red is lighted and present temp is lighted to HOT AIR TEMP Tcc is flickered to SETTING TEMP And It becomes blow operation condition Main cause When hot air circulation temp exceeded the upper limit of the suction gas temp of the hot air generator Return method Pleas...

Страница 12: ... the time of the furnace upper part establishment Return method Please stop operation by pushing STOP switch And please disarm by turning OFF the breaker NFB of this machine after inside temp of the hot air generator dropped At the time of the inside SSC temp warning of the hot air generator Only TSK 122 132 200V TEMP WARN lamp Red is flickered and SSc is flickered to HOT AIR TEMP ALM to SETTING T...

Страница 13: ...s are confirmed And please communicate the display contents The position of the inverter panel differs by the machine type TSK 18 Back side of the control panel service terminal TSK 23 33 The inside of the back panel TSK 42 52 The inside of the control panel Please open the control panel and please confirm TSK 52HT The inside of the back panel TSK 56 The inside of the control panel Please open the...

Страница 14: ...out fail when the wiring is confirmed and readjusted at the time of abnormal 13 8 4 Other warning Frequency warning Only TSK 52HT TSK 62 132 SYS is flickered to HOT AIR TEMP ALM to SETTING TEMP in the case that the frequency that is supplied from the primary power supply exceeded 3Hz of the ratings And all the operation stop Unsupply of rating frequency by the generator etc is used to the primary ...

Страница 15: ... generator is stopped at the time of the reverse connection of each temp sensor External sensor is included or perception of 15 ゚ C Only inside temp sensor is 10 ゚ C is flickered to HOT AIR TEMP display of each sensor to SETTING TEMP External sensor Tc0 Outlet sensor TcA Overheat sensor TcM Inlet sensor Tcc Inside temp sensor Tcb Main cause Reverse connection of the external sensor Reverse connect...

Страница 16: ...sales kansaidennetsu co jp Inquiry regarding the hot air generator Homepage www kansaidennetsu co jp or E mail ...

Отзывы: