20
11
11
11
11----4 Adjusting the guides
4 Adjusting the guides
4 Adjusting the guides
4 Adjusting the guides
■
Height adjustment
Clearance between elastic tape guard D and needle
plate mounting plate C is factory set at
approximately 5.0mm.
Adjust the clearance according to the fabric to be
used. Adjustment is made by loosening screws A
and moving guide holder (upper) up or down as
required.
■
Adjusting elastic tape left to right
Loosen screws A.
Position each elastic tape so that it cannot touch
each needle (see the illustration).
Adjustment is made by loosening screws A from the
hole on guide holder (upper) cover B and moving the
guide holder (upper) to the left or right as required.
■
Adjusting
the hem
width
Loosen screws A and B. Position fabric guide (right) C and fabric guide (front) D
according to the hem width. Adjustment is made by moving C and D to the left or right
as required.
Loosen screws
E and adjust
the height of
the fabric guide
(right).
Elastic tape
guard F should
be centered in
fabric guide
(right) C.
Move fabric guide (right) C slightly to the right according to the thickness of the fabric.