The thermostat has 3 menus: 

View 

- view the measured temperatures

Adjust 

- adjust the operating temperatures

Schedule 

- select a manual override

User Interface 

View the Indoor 

 Temperature

If an indoor sensor is active:

View the 

 Temperature

If a floor sensor is installed:

View the Outdoor 

 Temperature

If an outdoor sensor is installed:

View the Temperatures

Symbol Description

OFF

Thermostat is in the off mode of 
operation.

INSTALLER / USER

A padlock is shown while in the user 
access level.

WARNING

Shown when an error message is 
present.

INDOOR TEMPERATURE

Shown together with the measured 
indoor air temperature.

SLEEP

Shown while operating at the sleep 
temperature.

EXTERNAL NIGHT SETBACK

Shown when external night setback 
signal is present.

HEAT

Thermostat is in the heating mode of 
operation.

MANUAL OVERRIDE

Shown when an override is manually 
selected.

OUTDOOR TEMPERATURE

Shown together with the measured 
outdoor temperature.

INDOOR TARGET

Shown together with the desired indoor 
air temperature.

WAKE

Shown while operating at the wake 
temperature.

HEAT CONTACT

Shows when the heat contact is 
closed.

• 

• 

To change the Indoor Target: Press the up 

 or down 

 button.

• 

• 

To change the FLOOR MIN when there is no Indoor 

temperature: Press the up 

 or down 

 button.

• 

• 

Press the Menu 

 button to change the menu.

• 

• 

Press the Item 

 button to advance to the next item 

within a menu.

• 

• 

Press the up 

 or down 

 button to change the setting.

Содержание 506 Series

Страница 1: ...erride 4 Error Messages 4 Cleaning the Thermostat 4 Warranty 4 Features Large Multilingual Display Remote Air Sensing Manual Override Floor Heating Night Setback Backlight Display Item Field Displays an abbreviated name or symbol of the selected item Number Field Displays the current value of the selected item Status Field Displays the current status of the control s inputs outputs and operation M...

Страница 2: ...indoor air temperature SLEEP Shown while operating at the sleep temperature EXTERNAL NIGHT SETBACK Shown when external night setback signal is present HEAT Thermostat is in the heating mode of operation MANUAL OVERRIDE Shown when an override is manually selected OUTDOOR TEMPERATURE Shown together with the measured outdoor temperature INDOOR TARGET Shown together with the desired indoor air tempera...

Страница 3: ... temperature Wake is the normal operating temperature Sleep is the operating temperature while a night setback signal or manual override is present Wake Sleep Press the up or down button to permanently adjust the Floor Minimum temperature Wake is the normal operating temperature Sleep is the operating temperature while a night setback signal or manual override is present Select either C or F Press...

Страница 4: ...r ranty are the Purchaser s sole responsibility and obligation Purchaser shall indemnify and hold kanmor harmless from and against any and all claims liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers The pass through Limited Warranty does not apply if the returned Product has been damaged by negli...

Отзывы: