background image

#46673 User Guide

HeatLink

®

 Digital Heat/Cool Timer Thermostat

•  24Vac electronic thermostat with LCD display for hydronic fl oor heating systems and air 

conditioning.

•  Proportional Integral temperature regulation
•  Fully menu driven
•  Large display showing current temperature.
•  Setpoint display with push of a button.
•  Manual or automatic setback. Setback signal generator for other thermostats.
•  Floor warming functionality with room, fl oor or combined operation

(In combined operation the fl oor sensor acts as temperature limiter)

•  Silent (triac) output to be connected directly to actuators (see connecting drawing on the installation 

sheet) or to the StatLink

®

 system. (In this case, please refer to the StatLink

®

 module datasheet)

L646673 - February 26, 2007

HeatLink and StatLink are registered trademarks of HeatLink Group Inc.

Display

Optional external sensor
(sold separately)

PPL IMP 3107 A

Modes of Operation

Use the 

 and 

 keys to change the mode in the Operating mode menu

maintained). The ambient temperature is displayed.
Press 

 to display the anti-freeze temperature.

Pressing and holding the 

 button for 1-2 sec will 

display the software version.

 FAN mode:

Use the 

  or 

 keys to choose :

FAn OFF

”  the fan is always OFF.

FAn On

” 

the fan is always ON.

FAn Auto

”  the fan follows the cooling demand.

 Set CLOCK Menu:

Use this menu to adjust the clock.
Use 

 or 

 keys to adjust the minutes

After press 
Then use the 

 or 

 to adjust the hours 

After press 
Then use the 

 or 

 to adjust the day, 

Note: 1

st

 day of the week = Monday

After press 

P1:

 Morning, Evening & Weekend

P2:

 Morning, midday, Evening & Weekend

P3:

 Day & Weekend

P4:

 Evening & Weekend

P5:

 Morning, Evening (bathroom)

P6:

 Morning, Afternoon & Weekend

P7:

 7h - 19h (Offi ce)

P8:

 8h - 19h, Saturday (Shop)

P9:

 Weekend (Secondary House)

Note: 1

st

 day of the week = Monday

U1, U2, U3, U4: 

User defi ned

 HEAT / COOL / AUTO mode selection:

Use the 

  or 

 keys to choose :

Mod HEAT

” 

for heat mode  .

Mod COOL

”  for cool mode  .

Mod AUTO

”  for automatic mode 

.

Pressing the 

 key will put the thermostat back into 

 operation mode (equivalent to pressing 

 

twice).  The last displayed operation mode will be active.

 

STANDARD operating mode:

Force standard temperature operation indefi nitely.
Set standard operation temperature.

 

AUTOMATIC operating mode:

The thermostat will automatically follow the program set 
in the Program menu.
Temporarily override current operating temperature.

 MANUAL SETBACK operating mode:

Force setback temperature operation indefi nitely.
Set setback operation temperature.

 

 

 temperature adjustment

Pressing the 

 key will toggle the display between 

the measured and the setpoint temperature. Pressing 

 or 

 keys (regardless of displayed temperature) 

will enter temperature adjustment mode (setpoint 
temperature is displayed and blinks). Adjust by pressing 

 or 

 keys.

To adjust the heating temperature, ensure that the 
thermostat is in heating mode   (forced or automatic).
To adjust the cooling temperature, ensure that the 
thermostat is in cooling mode   (forced or automatic).
The thermostat will automatically maintain a 
2˚C separation between the heating and cooling 
temperature by adjusting the inactive temperature.
For example, if cooling was set to 22˚ and you adjust 
the heating from 18˚ to 21˚, then the cooling setpoint will 
automatically be adjusted to 23˚.
In 

 mode, any adjustment made is temporary 

and the 

 indicator will light up. At the next program 

change the 

 will disappear and the program will 

continue with the temperature set in 

 and  .

The measured   temperature reappears after a few 
seconds or by pressing the 

 key.

 FREEZE PROTECTION mode:

Use this mode if your heating installation needs to 
be turned OFF. (43°F/6°C anti-freeze temperature is 

 PROGRAM Menu:

You have the choice between 9 preset programs (P1 
to P9) and 4 user defi ned programs (U1 to U4).

By pressing 

 key the program number starts to 

blink and can be changed with 

 or 

 keys.

Press 

 or 

 

to view each day’s 
program.

daily program

continued on the next page

1:

 

Fan indicator / menu

2:

 

Temperature overridden

3:

 

Holiday indicators

4:

 

Operating mode menu

5:

 

Day of the week

 

1

st

 day of the week = Monday

6:

 

Time

7:

 

Current program settings

8:

 

Temperature display (measured   or setpoint)

9:

 

Measured temperature indicator

10:

  Cool demand indicator

11:

  Heat demand indicator

The heating and cooling indicators will display to 
indicate the mode of operation and blink to indicate 
a call for heat/cool.

5

6

4

7

9

10

11

3

2

1

8

Summary of Contents for 46673

Page 1: ... STANDARD operating mode Force standard temperature operation indefinitely Set standard operation temperature AUTOMATIC operating mode The thermostat will automatically follow the program set in the Program menu Temporarily override current operating temperature MANUAL SETBACK operating mode Force setback temperature operation indefinitely Set setback operation temperature temperature adjustment P...

Page 2: ...e it will measure the time taken by your system to reach the set temperature The thermostat will re measure this time at each program change to compensate for external temperature changes influences You can now program your thermostat without the need to compensate for the time it takes the system to respond because your thermostat does it for you automatically Measured temperature precision 0 1 C...

Page 3: ...urez vous que le thermostat est en mode refroidissement forcé ou automatique Le thermostat maintiendra automatiquement un écart de 2 C entre la température de chauffage et de refroidissement en ajustant la température inactive Par exemple si le refroidissement était réglé à 22 et que vous ajustiez le chauffage de 18 à 21 alors le point de réglage du refroidissement sera automatiquement ajusté à 23...

Page 4: ...c le chauffage rayonnant le système prend un certain temps avant de répondre En utilisant les programmes le système de contrôle intelligent de la température va activer votre système à l avance afin de s assurer que la température désirée sera atteinte à l heure convenue dans votre programmation hebdomadaire Le système de contrôle intelligent de la température fonctionne de la façon suivante Quand...

Page 5: ...cable FAS105 Codage de couleur basé sur le câble d alarme FAS105 Codificación de color basada en el cable la alarma de incendio FAS105 min 20 cm 8 150 cm 60 L646673 R C a b 24Vac Cooling System Contacts Contacts de dispositif de climatisation Contactos del sistema de aire acondicionado W Y A R C G D PPL IMP 3024 A ...