Service and Repair Manual
Model 1400KV/1400BV
FAULT FINDING
With the aid of the Fault Finding chart (below) the source of any malfunction may be quickly identified and repaired.
REMEDY FAULT
AND RETEST
MOTOR
REVOLVES?
MACHINE
HAMMERS?
MACHINE
IDLES?
SUPPLY
OK?
PLUG FUSE
OK?
BRUSHES
OK?
CORD
OK?
SWITCH
OK?
ARMATURE FIELD
INTERNAL
WIRING
SERVICE
MECHANISM
MODULE
WAS MOTOR
BURNT OUT?
MACHINE
OK
YES
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
NO
NO
LETHAL VOLTAGES PRESENT!!
On completion of the assembly, the unit must be flash tested at 4000 volts.
1. With the breaker completely assembled and with the switch “ON” apply 2000 volts initially and
increase rapidly to 4000 volts between the main casting and one of the pins of the plug on the power
supply cord. Apply test to both live and neutral pins.
2. The full voltage of 4000 volts should be maintained without breakdown or flashover for a few
seconds.
3. If the armature has been tested, remove the carbon brushes before carrying out the test, (thus
avoiding over-stressing the armature insulation system.)
4. The test voltage must be applied between the main casting and each live pin of the plug in
succession.
1. Ensure the unit is switched
ON
before testing. Operate the unit for approx. 10 minutes at
half
voltage for initial ‘bedding in’ of the carbon brushes followed by full operational voltage. Compare
readings with Performance Data.
WARNING
Important
Flash Test
Running Test