background image

2/11 

1. General Introduction 

1.1 JKA stager controller is the product developed on the basis of advanced technology. 
It is widely being applied in various water  treatment fields as Filtration System, Water 
Conditioning, Softening System and Desalination Systems, etc. The main distinguished 
features of JKA Controller are: 

Power: 150~250V/AC, 50/60Hz, 4W; 
Chinese or English version alternatively selected, setting simplicity, No complicated 
programming languages ability needed to operator; 
Password Protection design prevents parameter setting from arbitrary and unexpected 
alteration; 
Flexible  regeneration  initiation  modes  ( Volume,  Remote,  Interval,  Week 
timing ).The  selection  of  regeneration  modes  depends  on  specific  technical  and 
systemic conditions.   
LCD  display  with  backlight  for  over  ten  years  use  and  state  display  function  on 
panel; 
Regeneration and relevant outputs signals  are all Relay Dry Contractor; AC 220/5A; 
Remote control signal is dry contact. Signal can be reserved at least 2 seconds; 
JKA Stager Controller contains four specified parameters: 

a) Plan          b) M  program 

         c) S  program

          d) Commerce

 

Peripheral logic interlock function can be implemented among multiple JKA Stager 
Controllers through using S1 or S3 program  of one JKA Stager Controller as state 
feedback  to  adjacent  one.  Hereby,  Regeneration  initiation  on  two  JKA  Stager 
Controllers is thus avoided.   
JKA  Stager  Controller  equips  two  logic  level  control   units  with  Relay  Dry 
Contractor output; 
Commercial lock. Please  contact our technical pers onnel for detailed usage. 

1.2 Key and Display 
1.2.1 Keys 
The Six function keys, located directly beneath the display, control the majority of JKA 

Содержание JKA

Страница 1: ...JKA STAGER CONTROLLER SERVICE MANUAL Shahe Industrial Zone Changping District Beijing China 102206 Tel 86 010 69730336 Fax 86 01080706936 Email kj kangjiezc com www kangjiezc com ...

Страница 2: ...nd systemic conditions LCD display with backlight for over ten years use and state display function on panel Regeneration and relevant outputs signals are all Relay Dry Contractor AC 220 5A Remote control signal is dry contact Signal can be reserved at least 2 seconds JKA Stager Controller contains four specified parameters a Plan b M program c S program d Commerce Peripheral logic interlock funct...

Страница 3: ...lighting denotes cut off of high level contact point and extinguishing denotes connection of high level contact point Light B1 indicates low hydraulic level state of group one Namely lighting denotes cut off of low level contact point and extinguishing denotes connection of low level contact point Light C1 shows logic state output of hydraulic level of Group one Low level C1 is connected adversely...

Страница 4: ... Use keys to move cursor push key to modify value transfer 0000 to 2008 Then press ENTER to get into main menu screen displays as below 2 2 2 Time calibration Access to time calibration setting by pushing Clock and ENTER Screen displays as below If the time is not consistent with current time push and keys to adjust Then press ESC to return to main menu 2 2 3 Plan setting Move the cursor to Plan a...

Страница 5: ...regeneration initiation mode then move cursor to Volume and press ENTER to get into Volume mode setting display as below Note K value is pipe coefficient P is Total volume Press and keys to input K value and P value and then press ENTER to confirm Accumulative volume value checked by moving cursor on and press ENTER then display as below To remove accumulative volume value press ENTER on the above...

Страница 6: ...s and then press ENTER Note among four regeneration modes remote mode is highest priority namely no matter Week timing or Interval mode as long as Stager controller receives remote signal it will initiate regeneration program Business Lock if its function is needed please contact to us 2 4 M program Move cursor on M Prog and press ENTER to get into M program setting display as below Change number ...

Страница 7: ...ing move cursor to S Prog and press ENTER to access S program setting screen displays as below Sprogram includes 3 sub program can be set S1 S3 program setting select S1 or S2 program and then press to go into setting display Move cursor to certain which stage needs assistant signal output And then transfer to to activate S1 and S3 programs are restricted by M program on the number of stages and t...

Страница 8: ... SIGNET flow sensor is chosen linking red line of flow sensor to 16 terminal CPIN And black line and shield line both link to 15 terminal COM 14 terminal is no connection Instruction terminal 25 and 26 are two input points of external feedback signal Regeneration of JKA Stager Controller is restrained immediately when any of both forms short circuit with COM linking As far as releasing external fe...

Страница 9: ...rent systematic state information Under the working status display as below Acquire present date time and next regeneration time from main screen when Week timing mode is adopted Easily obtain volume flow rate on main screen when Volume mode is adopted Know present date time week and remote control mode when Remote mode is selected JKA stager controller activates regeneration when residual flow ra...

Страница 10: ...tiate regeneration Display as below When regeneration program initiated residual time of first stage decreases by 1 Till zero program goes into second stage Press ESC constant for 5 seconds to stop regeneration display as below 2006 03 21 TU 14 18 58 Next Remote ManuStep STEP 1 3 Left 600 强制 ...

Страница 11: ...2 0 8 1 2 installation pattern Support Base Union Connection Support Base Union Connection Support Base Union Connection Support Base Flange Connection Support Base Union Connection Control Principle Drawing Regeneration startup Normal work Program Startup Relay Motor Drive Relay 3s First stage 3s Second stage 3s Third stage Stager reposition S1 Output Relay S2 delay output relay 3 t S3 output rel...

Отзывы: