KANE900 Plus Operators Manual
Page 22
7.
STORING AND RETRIEVING DATA
The KANE900 Plus can store up to 100 combustion tests. Once stored, the data can
be viewed on the display or downloaded to a PC or printer.
7.1 Storing a ‘Live’ Test
While performing a test and viewing the data on the MAIN display access the STORE
menu as follows :-
STORE MENU
MODE
LOCATION
:
S
TORE
:
3
Press
to access the STORE MENU
PRESS ‘STORE’ TO LOG
Mode:
Select from the following :-
•
STORE
- Allows data to be stored in memory.
•
VIEW / PRINT
- Stored data can be viewed or printed.
•
DELETE
- Clears all data in memory.
Location:
Automaticaly allocates a location in the memory of the instrument for
the next test. On the display shown above the next location will be 3.
To store a test set
MODE
to
STORE
and press
. The current readings will
be stored in the analysers memory.
Tip :
Make a note of the location number for your particular test as it may be
useful when downloading or printing.
7.2 Viewing and Printing a ‘Stored’ Test
Multiple tests can be printed easily with the KANE900 Plus.
Select PRINT under MODE in the STORE menu. This feature is in addition to the
VIEW/PRINT, STORE and DELETE options.
STORE MENU
MODE
LOCATION
:
P
RINT
:
1 TO
10
Press
to access the STORE
MENU
PRESS ‘PRINT’
The cursor will move to the first number, use the
and
to select the
location and start printing.
Press
to move the cursor to the second number, select the last location to
print.
Keison Products www.keison.co.uk [email protected] Tel: 01245 600560 Fax: 01245 600030