Page 14
Follow the screen prompts precisely. Wait for the countdown and when
instructed the vehicle’s accelerator pedal must be fully depressed in a
smooth motion in under one second and held at full acceleration for a
period of three seconds until the screen shows “STOP”.
Repeat the sequence for a minimum of three or five times in order to get
the average reading required. The AUTO600 will average fewer readings
however.
The results of the individual tests and the average can be printed using
the Kane infrared printer. Ensure the emitter on the top of the handset
and the printer are lined up and in range, before pressing the print
button. Follow the screen prompts if further copies of the test results are
needed. If necessary the results can be printed from the normal screen,
but if the AUTO600 is switched off all information is lost.
NOTE:-
THESE READINGS CANNOT BE SAVED
A REPEAT TEST WILL REQUIRE A RE-ZERO
What should the readings be?
•
2.50k for vehicles with non-turbocharged engines, used before 1
July 2008
•
3.00k for vehicles with turbocharged engines, used before 1 July
2008
•
1.50k for vehicles used on or after 1 July 2008