6. USING THE KANE451 AS A THERMOMETER OR
PRESSURE METER
With the KANE451 switched off, press and hold down the
/
button and
then press and release
/
. Release
/
after MANO_MOD
is displayed on top line.
The KANE451 will now operate as a fixed display thermometer/pressure meter with
the pump off and inhibited. The readings can be printed but not stored.
The display will show:
P
0.00
→
Real time pressure reading.
T1
21.3
→
Use the T1 connection for the flow
temperature sensor.
T2
21.3
→
Use the T2 connection for the return
temperature sensor.
∆
T
0.0
→
Real time temperature difference.
The standard printout for this mode is as follows:
K451 1.0
YOUR COMPANY NAME &
PHONE NUMBER HERE
DATE 15/05/07
TIME 13:00:47
…………….…………………………
T1
o
C 21.3
T2
o
C 21.3
∆
T
o
C 0.0
PRS mbar
0.00
………………………………………
Ref.
………………………………………
Exit ‘Mano-Mod’ by switching the KANE451 off.
The ‘Menu’ and ‘Tighness’ positions still operate normally in ‘Mano-Mod’