background image

7.  SPECIFICATION 

 

Model: KANE3500-1 

 

Nominal Pressure Ranges 

 

mbar

 

mmH

2

O

 

Pa

 

kPa

 

 

80.00

 

800.0

 

 

8000

 

 

8.000

 

 

 
 

PSI

 

 

mmHg

 

 

hPa

 

 

inH

2

0

 

 

1.000

 

 

60.00

 

 

80.00

 

 

30.00

 

 

 
 

Model: KANE3500-2

 

 

Nominal Pressure Ranges 

 

mbar

 

 

mmH

2

O

 

 

Pa

 

 

kPa

 

 

160.00

 

 

1600.0

 

 

16000

 

 

16.000

 

 

 
 

PSI

 

 

mmHg

 

 

hPa

 

 

inH

2

0

 

 

2.000

 

 

120.00

 

 

160.00

 

 

60.00

 

 

 
 

Содержание 18965-2

Страница 1: ...KANE3500 PRESSURE METER Stock No 18965 2 June 2014 Kane International Ltd...

Страница 2: ...be live data frozen data or stored data 255 sets of tests can be stored in the non volatile memory Two lines of 20 characters can be added to the header of printouts The meter is controlled using 8 b...

Страница 3: ...he button is also a shortcut to the let by stabilization tightness test Only applies to KANE3500 1 UK and KANE3500 2 UK BOTTOM LINE OPTIONS The buttons change the bottom line of the display The bottom...

Страница 4: ...ot sure what the maximum pressure might be Always ensure that the meter you are using is correctly rated for the pressure that you intend to measure Excessive pressure 5 times nominal range can perman...

Страница 5: ...can be displayed in C or F AUTO OFF Auto power off timer in minutes Set at 00 to disable the auto power off SET TIME Uses Military time 7am 07 00 7pm 19 00 SET DATE Select format e g DD MM YY then set...

Страница 6: ...he meter in the orientation that it is being used This eliminates gravity effects on the very sensitive pressure transducer It is also recommend that the meter is switched on for at least five minutes...

Страница 7: ...EXAMPLE PRINTOUTS The standard printout is The MAX and MIN readings are those observed since last switch on NOTE Printouts of stored readings will also include the TEST NO below the header...

Страница 8: ...S 20 00 The stabilisation test counts down in seconds Duration is set via menu PS live pressure reading during the stabilisation period 8 TIME 00 PS 20 00 End of the stabilisation period Either press...

Страница 9: ...Let By Test and Tightness Test Printout NOTE Printouts of stored readings will also include the LOG NO Below the header...

Страница 10: ...r should be re calibrated and serviced annually by a Kane approved service centre Local regulations may require more frequent re calibration Calibration is performed in firmware and there are no user...

Страница 11: ...inal Pressure Ranges mbar mmH2O Pa kPa 80 00 800 0 8000 8 000 PSI mmHg hPa inH20 1 000 60 00 80 00 30 00 Model KANE3500 2 Nominal Pressure Ranges mbar mmH2O Pa kPa 160 00 1600 0 16000 16 000 PSI mmHg...

Страница 12: ...000 40 00 PSI mmHg hPa inH20 5 000 300 0 400 0 150 0 Model KANE3500 15 Nominal Pressure Ranges mbar kPa PSI 1040 0 100 00 15 00 mmHg hPa inH20 780 0 1040 0 400 0 Model KANE3500 30 Nominal Pressure Ran...

Страница 13: ...000 Pa 1 Pa 3 of reading 80 hPa 0 01 hPa 3 of reading Model KANE3500 2 Range Resolution Accuracy 20 Pa 0 3 Pa 2 Pa 2000 Pa 0 3 Pa 5 Pa 160 hPa 0 01 hPa 3 of reading Model KANE3500 5 Range Resolution A...

Страница 14: ...076 hPA 0 1 hPa 10 hPa 2070 0 hPA 1 hPa 3 of reading Dimensions Weight 310 grams with battery Handset 160mm x 80mm x 40mm 180mm incl spigots Ambient 0 C to 45 C Operating 10 to 90 RH non Range condens...

Страница 15: ...appropriate to check the meter before use by Use the normal start up sequence in the location where the meter will be used Switch on all localized electrical equipment capable of causing interference...

Страница 16: ...Specification EC EMC KI KANE3500 details the specific test configuration performance and conditions of use Please Note Batteries used in this instrument should be disposed of in accordance with curre...

Страница 17: ...e is recorded when each test is stored printed NOTE When changing the batteries on the instrument the memory will store the date and time for up to one minute if outside this time it may be necessary...

Страница 18: ...71JG Sending your KANE3500 Once the meter has been securely packed then your package is ready for shipment back to Kane If you do not have an account with a courier company you can take your package t...

Страница 19: ...Kane International Ltd Gibfield Park Avenue Atherton Manchester M46 0SY Southern Service Centre Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG Northern Servic...