11.9.1 Factory setting page
Start mode:
key, PLC, safe
Language:
Chinese, English
11.10 Amplitude calibration
Click Amplitude Adjustment to enter into this page. The password is “8080”.
Commissioning steps for constant welding:
1. Select constant welding function and adjust it
;
2. Set amplitude at 100%
;
3. Long press on ultrasonic TEST button
;
4. Watch system parameter and Constant Amplitude Range
;
5. Input the Minimum and Maximum value you have seen within the Constant
Amplitude Range;
6. Select ENABLE for the constant amplitude.
11.10.1 Functions and Parameter setting
Frequency search:
same as Trigger preparation page.
Ultrasonic test:
Same as Trigger preparation page.
Constant Amplitude function:
Enable, Adjust, Disable
Constant Amplitude Range Min
:
20-Max
Continuous Amplitude Range Max
:
Min-999.