background image

 
 
 
 
 

Waist-High  

Stand-On Scale 

Models 6855, 6855KGEU 

6856 & 6856KGEU 

Operating Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

CARDINAL SCALE MFG. CO. 

1930-M458-O1 Rev C 

PO BOX 151 

WEBB CITY, MO 64870

Printed in USA

04/09 

PH (417) 673-4631 

FAX (417) 673-5001

 

 

Web Site - http://www.detectoscale.com 

 

Technical Support: Ph: 866-254-8261 

y

 [email protected] 

Summary of Contents for Detecto 6855

Page 1: ...6 6856KGEU Operating Instructions CARDINAL SCALE MFG CO 1930 M458 O1 Rev C PO BOX 151 WEBB CITY MO 64870 Printed in USA 04 09 PH 417 673 4631 FAX 417 673 5001 Web Site http www detectoscale com Technical Support Ph 866 254 8261 y techsupport cardet com ...

Page 2: ......

Page 3: ... C 20402 Stock No 001 000 00315 4 All rights reserved Reproduction or use without expressed written permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual the Seller assumes no responsibility for errors or omissions Nei...

Page 4: ...1930 M458 O1 y Waist High 685X Series Page 2 This page intentionally left blank ...

Page 5: ...NOT use acetone thinner or other volatile solvents for cleaning DO NOT expose scale to temperature extremes DO NOT place scale in front of heating cooling vents DO NOT place scale in an area where it might be exposed to moisture DO clean the indicator with a damp soft cloth and mild non abrasive detergent DO remove power before cleaning with a damp cloth DO provide clean AC power and adequate prot...

Page 6: ...f the same type They must be all Alkaline Ni Cad or all NiMH In addition DO NOT mix Ni Cad or NiMH batteries CAUTION The scale indicator has internal circuitry that when used in conjunction with the external power supply recharges the Ni Cad or NiMH batteries Because the indicator has this charging capability DO NOT connect a power supply to the indicator if using Alkaline batteries Optional AC Po...

Page 7: ... all 6 batteries from the battery holder and then proceed to step 6 6 Install the 6 new AA size batteries in the battery holder noting the polarity markings located in the battery holder Refer to Figure No 5 7 After placing all 6 batteries in the holder replace the battery cover 8 Make sure power supply is unplugged and then turn indicator over display facing up and press ON OFF key 9 If display t...

Page 8: ...late BMI 1 Press ON OFF key to turn on indicator 2 Press ZERO key to zero weight display The ZERO and lb or kg annunciator will turn on to show that scale is ready for use 3 Place patient on scale and read weight display 4 Press BMI ENTER key 5 If pounds is the active weighing unit display will change to show 5 FEET 6 INCHES with the 6 blinking The blinking character is the position to be changed ...

Page 9: ...rom shipping container Inspect the unit for signs of damage Contact our Customer Service Department if necessary 2 Loosen screws located on front of scale column Place height rod brackets over screws and pull down securing brackets Tighten screws as needed NOTE The Indicator must be facing away from the scale platform to install the height rod Height Rod Operation 1 Raise the inner rod of the tele...

Page 10: ...1930 M458 O1 y Waist High 685X Series Page 8 PART IDENTIFICATION Indicator Alternate Mounting Configuration ...

Page 11: ...1930 M458 O1 y Waist High 685X Series Page 9 PART IDENTIFICATION CONT ...

Page 12: ...1930 M458 O1 y Waist High 685X Series Page 10 PART IDENTIFICATION CONT ...

Page 13: ...INDICATOR 8 1 1 0033 B438 OA MTG BRKT ASSY 750 9 4 4 6021 0665 MACHINE SCREW 6 32 X 375 PAN HD PHILLIP DR 10 1 1 391RV204 ELASTIC STOP NUT 11 1 1 6680 1043 GROMMET 12 1 1 1930 B336 1A COLUMN ASSEMBLY 13 1 1930 C337 08 COVER 1 1930 C451 08 COVER 6856 14 1 1 6024 0047 EXT STAR WASHER 1 4 15 1 1 6021 1423 TRUSS HEAD SCREW 1 4 20 UNC 2A X 1 2 16 1 1 0033 B110 08 UHMW DISK 17 1 1 6024 0004 FLAT WASHER ...

Page 14: ...e direct labor of the technician at the job site This limited warranty honors only labor performed by Detecto authorized dealers This warranty does not apply to peripheral equipment not manufactured by Detecto this equipment will be covered by certain manufacturer s warranty only This warranty does not include replacement of expendable or consumable parts This does not apply to any item which has ...

Page 15: ...onnection with the sale or use of the product Detecto will not be liable for consequential damages of any nature including but not limited to loss of profit delays or expenses whether based on tort or contract Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured The foregoi...

Page 16: ...1930 M458 O1 y Waist High 685X Series Page 14 ...