background image

 

                            www.kg-groep.com                                                                                                                  page 3

 

1

 

F

OREWORD

 

This 

owner9s 

manual must be thoroughly read and understood before using and operating the NANO 

MAR SYSTEM and is intended for end users. The NANO MAR SYSTEM and the associated connections 
must be installed, commissioned, and maintained by a skilled, knowledgeable, and competent person 
or organization that is appropriately qualified to perform this work and is familiar with the objective 
of the equipment and the associated technical terminology.  

2

 

C

ERTIFICATION

 

 

The NANO MAR SYSTEM has successfully passed CE and FCC, EMC testing according to  EN 50130, EN 
61000,  EN  55016,  47  CFR15-ICES-003,  ANSI  63.4,  IEC60945-pt11  and  a  DNV  marine  type  approval 
according the DNV Class Guideline 0339-2021, certificate TAA000037H. For that the NMS has endured 
extensive environmental tests such as vibration, dry heat, damp heat and cold tests in accordance 
with the requirements of the DNV-CG 0339 standard. 

3

 

I

NTRODUCTION

 

The purpose of the NANO MAR SYSTEM is to control and monitor a number of aerosol generators 
mounted on a ship as part of a fire extinguishing system. The NANO MAR SYSTEM is a compact and 
robust  stand-alone  fire  detection-extinguishant  release  system  designed  to  protect  various 
applications  like  electrical  cabinets,  engine  rooms  in  vessels,  yachts  and  other  small  areas  or 
equipment. The NANO MAR SYSTEM continuously senses its inputs and, in the event of a fire, gives 
the correct output to enable a product specific fire extinguishing. The NANO control panel has two 
fire  detection  zones,  any, or all  of which  can  contribute  to  the  extinguishant release  decision.  In  a 
marine application, it

9s

 NOT common for a fire suppression system to be released by automatic fire 

detector. By default, the NANO control panel is set to only manual release, but can also be changed 
to automatic & manual release via push buttons on the NANO control panel. 

 

4

 

M

AINTENANCE 

&

 

C

LEANING

 

There are not user-replaceable parts in the NANO MAR SYSTEM. Take Electrostatic Discharge (ESD) 
precautions when opening the NANO control panel or NANO ETB BOX. Avoid direct contact with any 
of the components or connectors connected to the printed circuit board. Failure to follow accepted 
ESD handling practices could cause damage to the NANO MAR SYSTEM. Before starting the cleaning 
process, bring the system out of operation to prevent an unwanted fire extinguishing system release. 

It is important to note that improper cleaning of the NANO control panel front can damage this panel 
inhibit their ability to sense fire and activate the fire  extinguishers. To remove dust and contaminants, 

use nonalcoholic

 products which has been designed for that purpose.  

 

 

Do not use high pressure or stream cleaners

 

Содержание NANO MARINE

Страница 1: ...www KG Groep com January 1 2023 version 1 0 Owner s manual NANO MARINE FIRE DETECTION EXTINGUISHING CONTROL SYSTEM...

Страница 2: ...6 EXTINGUISHING RELEASE 6 9 LED INDICATORS 7 9 1 MANUAL RELEASE ONLY 7 9 2 AUTOMATIC MANUAL RELEASE 7 9 3 POWER 7 9 4 COMMON FIRE 7 9 5 FIRE ZONE ALARM 7 9 6 EXTINGUISHING RELEASED 8 9 7 EXTINGUISHING...

Страница 3: ...abinets engine rooms in vessels yachts and other small areas or equipment The NANO MAR SYSTEM continuously senses its inputs and in the event of a fire gives the correct output to enable a product spe...

Страница 4: ...depending on the DIP switch time settings In a marine application it is NOT common for a fire suppression system intended for an engine room to be released by an automatic fire detector But the NANO c...

Страница 5: ...nt of a complete power failure the general fault relay becomes inactive 6 7 VFC FIRE RELAY ACTIVE IN SINGLE OF DUAL MODE ALARM A single or dual FIRE indication can trigger the VFC relay You can choice...

Страница 6: ...d button as long this button is pressed the extinguishing release sequence will be halted and cause the yellow hold activated indicator flash Release the Hold button shall re start the countdown relea...

Страница 7: ...differently indicating an abnormality in the power supply to the NANO control panel When starting the NANO MAR SYSTEM after a power failure or an extinguishers release the green power LED on the NANO...

Страница 8: ...ators flash This yellow fault indicator will light continuously at any fault condition or power malfunction 9 9 FIRE ZONE FAULT When the NANO control panel has detected an error in one of the critical...

Страница 9: ...m Note the time the fire alarm occurred and log the fire event in the logbook 11 2 WHAT TO DO IN THE EVENT OF A FAULT CONDITION Note the indications on the front of the NANO control panel Note the tim...

Страница 10: ...sconnect extinguisher MOVE the disconnect switch of all in the YES position and the aerosol extinguisher is disabled and can not be activated A disablement will be signalized as fault on the NANO cont...

Страница 11: ...ystem according to the instructions of the supplier 12 4QUARTERLY TESTING COMPETENT PERSON To be conducted by the Competent Person Included as reference for the Premises Management Check all previous...

Страница 12: ...itness for a particular purpose It is the responsibility of the premises management to define the fire procedures and ensure that all relevant users are trained and that fire drills are performed with...

Отзывы: