background image

                                      

                                             

Owners’ m

anual

 

|

 

NANO MAR  SYSTEM | January 1, 2023 | version 1.0   page 2

 

 

 

TABLE OF CONTENTS

 

 

1

 

FOREWORD 

3

 

2

 

CERTIFICATION 

3

 

3

 

INTRODUCTION 

3

 

4

 

MAINTENANCE & CLEANING 

3

 

5

 

KEY PROPERTIES 

4

 

6

 

FEATURES OF THE NANO MAR SYSTEM 

4

 

6.1

 

A

COUSTIC ALARM

 

4

 

6.2

 

E

XTINGUISHANT RELEASE OUTPUT

 

4

 

6.3

 

H

ISTORIC EVENT LOG

 

5

 

6.4

 

C

OMMUNICATION PORT

 

5

 

6.5

 

D

IRECT RELEASE

 

5

 

6.6

 

G

ENERAL FAULT RELAY

 

5

 

6.7

 

VFC

 FIRE RELAY ACTIVE IN SINGLE OF DUAL MODE ALARM

 

5

 

6.8

 

S

INGLE OR DUAL ZONE

 

5

 

6.9

 

E

XTINGUISHANT RELEASE DELAY

 

5

 

7

 

NANO CONTROL PANEL FACIA 

5

 

8

 

CONTROL BUTTONS 

6

 

8.1

 

M

UTE

   

6

 

8.2

 

R

ESET

   

6

 

8.3

 

L

AMP TEST

 

6

 

8.4

 

H

OLD EXTINGUISHING RELEASE

 

6

 

8.5

 

A

UTOMATIC 

&

 MANUAL RELEASE OR MANUAL ONLY MODE

 

6

 

8.6

 

E

XTINGUISHING RELEASE

 

6

 

9

 

LED INDICATORS 

7

 

9.1

 

M

ANUAL RELEASE ONLY

 

7

 

9.2

 

A

UTOMATIC 

&

 MANUAL RELEASE

 

7

 

9.3

 

P

OWER

  

7

 

9.4

 

C

OMMON FIRE

 

7

 

9.5

 

F

IRE ZONE ALARM

 

7

 

9.6

 

E

XTINGUISHING RELEASED

 

8

 

9.7

 

E

XTINGUISHING DELAYED

 

8

 

9.8

 

G

ENERAL FAULT

 

8

 

9.9

 

F

IRE ZONE FAULT

 

8

 

9.10

 

E

XTINGUISHING RELEASE HOLD

 

8

 

9.11

 

E

XTINGUISHING RELEASE FAULT

 

8

 

9.12

 

I

NTERNAL FAULT INDICATORS

 

8

 

10

 

COMMON SETTINGS 

9

 

11

 

WHAT TO DO RECOMMENDATIONS 

9

 

11.1

 

W

HAT TO DO IN THE EVENT OF A FIRE ALARM CONDITION

 

9

 

11.2

 

W

HAT TO DO IN THE EVENT OF A FAULT CONDITION

 

9

 

11.3

 

R

OUTINE TESTING RECOMMENDATIONS

 

9

 

11.4

 

W

ARNING

 

9

 

12

 

MAINTENANCE RECOMMENDATIONS 

10

 

12.1

 

T

EST THE 

NANO

 SYSTEM WITHOUT ACTIVATING THE EXTINGUISHERS

10

 

12.2

 

D

AILY TESTING 

(P

REMISES 

M

ANAGEMENT

11

 

12.3

 

W

EEKLY TESTING 

(P

REMISES 

M

ANAGEMENT

11

 

12.4

 

Q

UARTERLY TESTING 

(C

OMPETENT 

P

ERSON

11

 

12.5

 

Y

EARLY TESTING 

(C

OMPETENT 

P

ERSON

11

 

13

 

WARRANTY 

12

 

Содержание NANO MARINE

Страница 1: ...www KG Groep com January 1 2023 version 1 0 Owner s manual NANO MARINE FIRE DETECTION EXTINGUISHING CONTROL SYSTEM...

Страница 2: ...6 EXTINGUISHING RELEASE 6 9 LED INDICATORS 7 9 1 MANUAL RELEASE ONLY 7 9 2 AUTOMATIC MANUAL RELEASE 7 9 3 POWER 7 9 4 COMMON FIRE 7 9 5 FIRE ZONE ALARM 7 9 6 EXTINGUISHING RELEASED 8 9 7 EXTINGUISHING...

Страница 3: ...abinets engine rooms in vessels yachts and other small areas or equipment The NANO MAR SYSTEM continuously senses its inputs and in the event of a fire gives the correct output to enable a product spe...

Страница 4: ...depending on the DIP switch time settings In a marine application it is NOT common for a fire suppression system intended for an engine room to be released by an automatic fire detector But the NANO c...

Страница 5: ...nt of a complete power failure the general fault relay becomes inactive 6 7 VFC FIRE RELAY ACTIVE IN SINGLE OF DUAL MODE ALARM A single or dual FIRE indication can trigger the VFC relay You can choice...

Страница 6: ...d button as long this button is pressed the extinguishing release sequence will be halted and cause the yellow hold activated indicator flash Release the Hold button shall re start the countdown relea...

Страница 7: ...differently indicating an abnormality in the power supply to the NANO control panel When starting the NANO MAR SYSTEM after a power failure or an extinguishers release the green power LED on the NANO...

Страница 8: ...ators flash This yellow fault indicator will light continuously at any fault condition or power malfunction 9 9 FIRE ZONE FAULT When the NANO control panel has detected an error in one of the critical...

Страница 9: ...m Note the time the fire alarm occurred and log the fire event in the logbook 11 2 WHAT TO DO IN THE EVENT OF A FAULT CONDITION Note the indications on the front of the NANO control panel Note the tim...

Страница 10: ...sconnect extinguisher MOVE the disconnect switch of all in the YES position and the aerosol extinguisher is disabled and can not be activated A disablement will be signalized as fault on the NANO cont...

Страница 11: ...ystem according to the instructions of the supplier 12 4QUARTERLY TESTING COMPETENT PERSON To be conducted by the Competent Person Included as reference for the Premises Management Check all previous...

Страница 12: ...itness for a particular purpose It is the responsibility of the premises management to define the fire procedures and ensure that all relevant users are trained and that fire drills are performed with...

Отзывы: