Horis User Manual
2.8
Maintenance
Battery full and not charging.
Battery half full.
Battery almost empty - less than 10%.
Battery charging and almost full.
Battery almost empty and charging.
Battery is currently too cold/hot for charging.
Table 10:
Battery status.
2.8
Maintenance
No special maintenance is required. A static leak test should be
performed annually and calibration check biannually. In case of small
deviation use the procedure described in Section 4.6.8.
2.9
Repair
Horis has no repairable parts inside. In case of malfunction it must
be sent to factory for repair.
2.10
Horis Use in Gliders
Experience shows that Horis can be successfully used also in gliders.
Sustained turns do not effect Horis, as long as turns are coordinated
(no significant slips or skids) and even in the continuous slip case,
only minor error in the bank appears.
However, low battery voltages may affect Horis operation. Although
Horis works also with voltages as low as 9 V, a problem may appear
even at higher voltages. A typical scenario (where gyros inside Horis
go crazy) happens when battery is at its low end (say at 11 V – with
31
©
Kanardia
2021
Содержание Horis
Страница 2: ......