KAMWELD KAM-TC1000 Скачать руководство пользователя страница 15

15 

be displayed then. 

30

Lock

188

AH

290

AL

0

AST

ON

SET

3 sec

SET

SET

SET

SET

SET

SET

SET

Figure 10. Parameter setup flow chart under (code 188). 

6.

 

Save and recall 

Program

This  controller  can  save  up  to  8 

Program

.  Each 

Program

  file  can  have  up  to  6  steps  (C-1  to 

C-6). For convenience, we have pre-named these 8 pieces of 

Program

 files as B1  ,  B2,  C1  , 

C2,  F1  ,  F2,  P1  ,  and  P2. These 

Program

 files  are  all  the same  except  their  names,  so  you 

can  store  your  special 

Program

  to  any  of  them.  These 

Program

 can be stored in the memory 

of the controller even when it is powered off. You can overwrite the exist 

Program

 with a new 

one.  

6.1 

  Save a 

Program.

 

After a program has been entered, the user can save this current program as a 

Program

 for 

future use.  Under  the  normal  operating  mode,  press  and  hold  SET  key  for  3  seconds 
until  the Parameter Window displays “LoCK”. Release the SET. The display will show “0”. Use 
“+” and “-” keys to adjust the display to 2 and press SET. The display will show “SAVE” for a 
second and then  the  value  “End”.  If  press  SET  key  now,  you  will  exit  this  mode  without 
overwriting  any existing programs. Use “+” or “-” key to select the name of 

Program

 to which 

you want to store the program. If you press “+” (or “-” key) repeatedly, you will see “End”, “b1”, 
“b2”, “C1”, “C2”, “F1”, “F2”, “P1”, “P2” one by one. Press the SET key again to store your 
current program under the selected 

Program

  name.  This  process  will  overwrite  the  current 

Program

  data  to the  saved 

Program

 data. Figure 11 shows the flow chart of how to save a 

Program

Содержание KAM-TC1000

Страница 1: ...emperature and high wattage appliances and your safety is paramount SAFETY WARNINGS This controller is designed only to be used with limited power device and paring thermal cutoff protection such as a...

Страница 2: ...ler off unplug the power cord and contact Kamweld Industries at 617 558 7500 before using it again Clean the controller only when it is cool and unplugged Specifications Input voltage 100 to 240 VAC 5...

Страница 3: ...ff the heater power is off When it is flashing it means the heater is on and off intermittently to reduce the power output 3 SET Key For showing current temperature settings entering parameters settin...

Страница 4: ...ing indicator A dot at the lower right corner When the dot flashing the value is editable pressing the or key to change the value The layout of the controller back panel is shown in Figure 2 Figure 2...

Страница 5: ...the power switch to turn on the controller The LED display will show 8 8 8 8 for 2 seconds and then display the current temperature Then turn off the controller Plug the power cord from the device WEL...

Страница 6: ...gram the time of the rest of the steps to zero To program the temperature profile press SET key once The display will show C 1 for one second and then display the temperature setting for step 1 Use an...

Страница 7: ...T SET Figure 5 Temperature profile programming flow chart Here is the one step heating program The temperature profile is programmed to start at 150 F for 600 minutes of heating Table 1 Initial progra...

Страница 8: ...when you first press key controller will show P 2 in the window If then you press Time key the controller will show P 40 with the Time Indicator lit At normal operating mode press the Time key item 6...

Страница 9: ...perating the controller in Fahrenheit you need to divide the P by 1 8 when changing the temperature unit to Celsius ON OFF mode If P is set to 0 the control mode will be changed from PID mode to ON OF...

Страница 10: ...ater 1 second for every 10 seconds This parameter should set at 2 second for heating with an electric heater When controlling a solenoid valve or a compressor of refrigerator the T should be set to 10...

Страница 11: ...lue should be 2 for most application After change the PID parameter the controller needs to be turned off and on again for the best result 30 Lck 166 P 7 I 600 d 150 at 0 t 2 SET 3 sec SET SET SET SET...

Страница 12: ...sate for the error produced by sensor Each unit is 1 degree e g if the temperature displays 2 C in ice water mixture set SC 2 will make the display to shown 0 degree OUT Output power reduction It is e...

Страница 13: ...delay The Anti short is the delay time to turn on the cooler E g refrigerator If the cooler is compressor based compressor should not be turned on immediately when it is at high pressure just after t...

Страница 14: ...le if AH set to 290 the buzzer will be on at 291 and off at 290 When the buzzer is on the display window will flashing between AH1 and the current temperature AL Low limit alarm for probe For example...

Страница 15: ...a program has been entered the user can save this current program as a Program for future use Under the normal operating mode press and hold SET key for 3 seconds until the Parameter Window displays L...

Страница 16: ...show 0 Use and keys to adjust the display to 1 and press SET The display will show rC for a second and then the value End If press SET key now you will exit this mode without overwriting any existing...

Страница 17: ...l operating mode to recall a Program press and hold SET key for 3 seconds until the Parameter Window displays LOCK Release the SET The display will show 0 Use and keys to adjust the display to 3 and p...

Страница 18: ...T briefly and enter the program below C 1 120 t 1 2 0 C 2 290 F 2 160 C 3 130 F 3 30 0 You can leave the rest of steps as their default values To store to Program b1 long press SET key set LoCK 2 choo...

Страница 19: ...ent single step program is C 1 120 3 Set current C 1 to 200 then store current program back to recipe b1 Now the b1 recipe is C 1 200 4 Change PrG y current b1 recipe is C 1 200 F 1 2 0 C 2 190 F 2 16...

Страница 20: ...erating mode press and hold SET key for 3 seconds until LED display LoCK and then release the SET key The display will show 0 then Use key to adjust the number to 50 and press SET key again to enter T...

Страница 21: ...current will produce about 1 3 watts of heat When 12 Amp is passing through the controller 16 watt of heat is produced in the controller As more heat is produced the temperature inside the controller...

Страница 22: ...rmation will also help you to manage the heat Place the controller in the right place The SSR of Auber WS series controller is mounted in the bottom of chassis The chassis is made of 3 mm thick alumin...

Отзывы: