TECHNICAL DESCRIPTION
ULTRAFLOW® 54 DN150-300
Kamstrup A/S
·
Technical description
·
5512-876_M1_GB_12.2020
30
Cable connections
Cable dimension in connections: 4.5…10 mm.
Tightening torque: Maximum 4 Nm (cable strain relief minimum 40 N according to EN 61558)
Please note: If ULTRAFLOW® 54 is mounted with a galvanically coupled output module, or if a galvanically separated
output module is used in combination with battery supply the unused cable connection must be sealed off as shown in
Change of supply unit
The supply unit of ULTRAFLOW® 54 can be changed from mains supply to battery or vice versa as the needs of the supply
company change. Thus, it can be an advantage to temporarily change mains supplied meters to battery supplied meters
e.g. in case of buildings under construction where the mains supply can be unstable or periodically missing.
Please note that the supply type of some ULTRAFLOW® sensors appears from the label. If the original supply type is
changed, it will no longer be in accordance with the label.