Output using Pulse Transmitter/Pulse Divider with galvanically separated output module (Y=3)
Type
Open collector. Three-wire connection via the built-
in 39.2 kΩ pull
-up resistor.
Module Y=3
OC and OD
Max input voltage
6 V
Max input current
0.1 mA
ON condition
U ≤ 0.3 V @ 0.1 mA
OFF condition
R ≥ 6 MΩ
Table 30
Figure 61. Block diagram for galvanically separated output module (Y=3).
8.3
Suggested test points
Nom. flow
Meter factor
q
p
q
p
q
i
0.1xq
p
q
p
q
i
0.1xq
p
q
p
q
i
0.1xq
p
[m³/h]
[pulses/l]
[m³/h]
[m³/h]
[m³/h]
[min]
[min]
[min]
[kg]
[kg]
[kg]
0.6
300
0.6
0.006
0.06
3
20
6
30
2
6
1.5
100
1.5
0.015
0.15
3
20
6
75
5
15
2.5
60
2.5
0.025
0.25
3
20.2
6
125
8.4
25
3.5
50
3.5
0.035
0.35
3
17.1
6
175
10
35
6
25
6
0.06
0.6
3
20
6
300
20
60
10
15
10
0.1
1
3
20.4
6
500
34
100
15
10
15
0.15
1.5
3
20
6
750
50
150
25
6
25
0.25
2.5
3
20.2
6
1250
84
250
40
5
40
0.4
4
3
15
6
2000
100
400
60
2.5
60
0.6
6
3
20
6
3000
200
600
100
1.5
100
1
10
3
20
6
5000
333
1000
Test quantities
Test duration
Test point
Table 31. Table for ULTRAFLOW
including suggested test points, test durations and test quantities.
The suggested test parameters are based on EN 1434-5 and q
p
:q
i
100:1.
The test set-ups have been selected on the basis of the following requirements:
•
Minimum test duration of 3 minutes
•
Water volumes at q
i
and 0.1 x q
p
of minimum 10 % of the water volume per hour
•
Water volume at 0.1 x q
p
corresponding to minimum 1000 pulses
•
Water volume at q
i
corresponding to minimum 500 pulses