6.7.2
Wall-mounting of Pulse Transmitter and Pulse Divider
'
At medium temperatures above 90 °C and below the ambient temperature, calculator and Pulse Transmitter/Pulse
Divider must not be mounted on the flow sensor. Instead wall-mounting is recommended.
Wall mounting of MULTICAL® and Pulse Transmitter/Pulse Divider protects these instruments against overheating in a
heat installation and condensing water in a cooling installation.
Figure 21. Pulse Transmitter/Pulse Divider
mounted on fitting 3026-207.A
6.8
Mounting of Cable Extender Box
Cable Extender Box is lightweight and can therefore hang freely as an integrated part of the signal cable from the
ULTRAFLOW® flow sensor to the calculator. Alternatively, Cable Extender Box can be wall-mounted. The base part of
Cable Extender Box contains 2 holes for this purpose, which are prepared for mounting screws.
6.9
Maintenance and service during operation
The flow sensor is verified separately and can, therefore, be separated from the calculator. See the sealing drawings of
the connected calculator such as MULTICAL® 603 (5512-2029_GB) or MULTICAL® 803 (5512-2360_GB).
Due to the sealing levels of Pulse Transmitter/Pulse Divider (see
), it is also permitted to replace the supply and
exchange the supply type in Pulse Transmitter/Pulse Divider while ULTRAFLOW® is installed in the installation. For battery
supply of Pulse Transmitter/Pulse Divider, a lithium battery with connector from Kamstrup A/S must be used. Lithium
batteries must be correctly handled and disposed of (see chapter
). It is also permissible to replace output
modules of Pulse Transmitter/Pulse Divider.
The cable length between ULTRAFLOW® and the MULTICAL® calculator may be extended under certain installation
conditions, for example by use of Cable Extender Box, up to max 30 m (see
Other repairs of ULTRAFLOW® and Pulse transmitter/Pulse Divider require subsequent reverification on accredited
laboratory.