TECHNICAL DESCRIPTION MULTICAL
®
401
5512-091 GB/02.2008/Rev. J1
22
5
Pressure loss
The pressure loss in a flow sensor is stated as the max. pressure loss at q
p
. According to EN 1434 the max.
pressure loss must not exceed 0.25 bar, unless the energy meter has a flow controller or functions as pressure
reducing equipment.
The pressure loss in a meter increases by the square of the flow and can be stated as:
p
kv
Q
Δ
×
=
where:
Q =volume flow rate [m³/h]
kv=volume flow rate at 1 bar pressure loss [m³/h]
Δ
p=pressure loss [bar]
q
p
Nom. diameter
Graph
[m³/h]
[mm]
kv
[m³/h]
A
0.6 & 1.5
DN15 & DN20
3
1.5
B
3 & 3.5 & 6
DN20 & DN25
13.5
6.8
C
10 & 15
DN40 & DN50
43
21.7
Table 5: Pressure loss table
Diagram 2: Pressure loss graphs
Δ
p MULTICAL
®
401
0,01
0,1
1
0,1
1
10
100
Flow [m³/h]
Δ
p [bar
]
A
B
C