background image

Kamoer Fluid Tech(Shanghai) Co.,Ltd                                                                                          Reef Master CMK User Manual

 

15 

APP Operation 

Distribution Network Equipment                                                                                 

The  app  requires  a  network  connection  to  set  and  read  device  parameters,  so  the  device 

configuration needs to be connected to the network. On the homepage of the device list, click the 

add button in the upper right corner to enter the device's distribution interface. Click Reef Master 

device  or  other  devices  to  enter  the  Bluetooth  connection  interface,  and  find  the  corresponding 

device  serial  number,  such  as  KAMOER_  CMK_  xxxxxxx,  click  to  enter  and  follow  the  interface 

prompts to distribute the network. 

 

 

Содержание Reef Master CMK

Страница 1: ...Reef Master CMK User Manual A1 2023 11 27 Kamoer Fluid Tech Shanghai Co Ltd www kamoer com...

Страница 2: ...to understand the usage process Please read the Reef Master CMK User Manual for detailed product information Quick search keywords PDF electronic documents can be searched for keywords using the searc...

Страница 3: ...packing packaging materials should be kept out of reach of children Children and vulnerable groups with limited physical sensory or mental abilities are not allowed to use this device and those who ar...

Страница 4: ...r installing the app open it and click the button in the upper right corner of the device page to enter the tutorial page Click to enter the corresponding device model including user manual and freque...

Страница 5: ...Overview 7 Introduction 7 Functional Highlights 7 Application Occasions 8 Unpacking Preparation 8 Component Name 9 Display Screen Status Description 10 First Use 13 Product Installation 13 APP Operat...

Страница 6: ...o Linkage Function 26 Device Binding 28 Use of Titration Equipment 30 Use of Calcium Reactor Equipment 31 Maintenance Function 34 Running and Stirring 36 Empty All Pipelines 37 Test Value Correct 38 T...

Страница 7: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 6 Product Overview This chapter mainly introduces the characteristics application scenarios and unboxing instructions of Reef Master CMK...

Страница 8: ...apps When there is an abnormality in the test value the device will automatically push an alert to the App The equipment can also control the titration pump or calcium reflux pump based on the test r...

Страница 9: ...mixed coral SPS LPS Other situations that require testing of water quality parameters such as calcium magnesium and KH Unpacking Preparation Before opening the packaging box check whether the outer pa...

Страница 10: ...te liquid pipe 2 meters 7 Testing reagents Component Name 1 2 3 8 4 5 9 6 7 10 11 1 Color display screen 2 Front cover shell 3 Front hood decorative light 4 External communication interface 5 DC24V po...

Страница 11: ...cium value and status display green indicates low test value red indicates high test value and white font indicates normal test value 4 The latest test magnesium value and status display green indicat...

Страница 12: ...g the latest parameter which is a type of calcium magnesium and KH 8 Time of Next Test Value The planned time of the next test parameter which is a type of calcium magnesium and KH If there is a detec...

Страница 13: ...Tech Shanghai Co Ltd Reef Master CMK User Manual 12 First Use This chapter mainly introduces how to check and confirm the normal operation of various functions of the equipment after assembly for the...

Страница 14: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 13 First Use Product Installation Reagent bottle installation Remove the original reagent bottle cap...

Страница 15: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 14 APP Operation This chapter mainly introduces how to use the app to operate Reef Master CMK...

Страница 16: ...tion needs to be connected to the network On the homepage of the device list click the add button in the upper right corner to enter the device s distribution interface Click Reef Master device or oth...

Страница 17: ...list to enter the Reef Master operation interface The interface module functions are as follows a Status The status module displays various status information of the device such as The latest detecte...

Страница 18: ...n the detection status Green indicates low value black indicates normal and red indicates high value c The latest magnesium value detected measured in ppm will change the background color in the displ...

Страница 19: ...lace the reagent When the number of tests is less than 5 the equipment will stop testing and the testing will only continue after the customer replaces the reagent Reagent Bottle Remaining Quantity Se...

Страница 20: ...ity on the interface the remaining quantity can be modified to be smaller d Concentration coefficient displaying the concentration coefficient of reagents different reagents have different concentrati...

Страница 21: ...day within a week c The schedule for KH testing can be set separately for each day of the week d Immediate detection If you want to start a detection immediately when there is no plan to run it you ca...

Страница 22: ...ng for the project Example Conduct a calcium and magnesium test on Monday at 02 00 First click on the Monday tag g click on the calcium and magnesium testing item tag i click on the 02 00 tag in the b...

Страница 23: ...led the measurement is based on the retest value a Automatic detection plan switch When the switch is turned off automatic detection will not be performed b Retest Click to enter the retest parameter...

Страница 24: ...ll be triggered e Validity period The interval between this test and the last test If the interval between this test and the last test is within this duration and the concentration of this test meets...

Страница 25: ...historical value of the corresponding position e Deadline displaying the current chart s deadline f The start time of detection items in the history table g Test values of detection items in the histo...

Страница 26: ...Maintain Here you can manually run the equipment s pump magnetic stirring etc to fill or empty the pipeline and check if the equipment s pump or magnetic stirring is running properly f Use guidance He...

Страница 27: ...ameters to factory settings j Remove Device Unbind App and device Linkage Function Introduction to Linkage Function The linkage function refers to the Reef Master s linkage between the titration pump...

Страница 28: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 27 Reef Master linked calcium reactor pump...

Страница 29: ...ium reflux pumps e Tank Volume which refers to the volume of water in the cylinder The equipment will calculate the amount that needs to be adjusted based on the volume of water in the cylinder and th...

Страница 30: ...adjusting water quality parameters through titration When the switch is turned on the titration adjustment parameters take effect c Adjusting water quality parameters through a calcium reactor d The f...

Страница 31: ...ording to the App s instructions c Connection guide you can refer to the guide to connect Reef Master and titration pump d Communication address wired communication address used when binding Reef Mast...

Страница 32: ...lete this adjustment k Stop Adjusting When you want to stop the adjustment of the titration pump you can click to stop this adjustment l Examples of adjusting according to proportion and quantity For...

Страница 33: ...n be adjusted by detecting the KH value c The operating time of the calcium reactor pump Set the operating time of the calcium reactor pump When the KH value is detected to be too low the Reef Master...

Страница 34: ...d calcium reactor pump via wireless server f Switch for scene control Scene operation takes effect when the switch is turned on g Running logs View the log of calcium reverse pump operation here h Cre...

Страница 35: ...valve maintenance peristaltic pump operation liquid filling and discharge calibration optical path inspection etc which can facilitate the maintenance of the Reef Master From System Settings Click Mai...

Страница 36: ...use standard solution to calibrate the measurement results of Reef Master When there is suspicion that the device is measuring inaccurately calibration can be performed to correct the device s detecti...

Страница 37: ...lso be set a Empty all liquids in the tube click to enter the empty liquid guide page b The magnetic stirring setting of the calcium magnesium KH detection module can set the operating intensity and s...

Страница 38: ...revent the overflow of liquid in the equipment pipelines from affecting transportation or storage a Empty all liquid in the pipeline When the equipment is not in use it is necessary to empty the liqui...

Страница 39: ...rected The corrected reference value can be the value of the test standard solution or the value of other considered accurate testing equipment It is recommended to use the standard solution for calib...

Страница 40: ...a Click to enter the detection value correction process select the parameters that need to be calibrated and then go to correct b Previously detected detection values c Input actual detection value d...

Страница 41: ...of the device titration plan a Firmware Time This displays the current real time clock time of the device b App time The current time of the phone c Time synchronization After clicking the device wil...

Страница 42: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 41 Equipment Maintenance...

Страница 43: ...ing when troubleshooting first remove the front cover b of the Reef Master shown in the figure below Go to System Settings Maintain Running Pumps to enter the control interface for Running and Stirrin...

Страница 44: ...n magnetic stirring it is possible that the magnetic stirring force has changed The problem can be solved by setting different magnetic stirring forces on the App The operating force of magnetic stirr...

Страница 45: ...Kamoer Fluid Tech Shanghai Co Ltd Reef Master CMK User Manual 44 Appendix...

Страница 46: ...g to the user manual and any man made faults or damages are not covered by the warranty Please keep the purchase invoice and user manual properly so that you can receive satisfactory after sales servi...

Страница 47: ...er supply 4 Damage to components caused by circuit board short circuits caused by the entry of various insects into the machine 5 Losses caused by accidents 6 Using inappropriate spare parts not appli...

Страница 48: ...Songjiang District Shanghai China Phone 86 021 67742578 Website www kamoer com Kamoer is a registered trademark of Kamoer Fluid Tech Shanghai Co Ltd The company reserves the right to improve and chang...

Отзывы: