exceptionally  cold  environment,  battery  service  life  may  be 

shortened,  and  there  may  be  a  drop  in  performance.  If  at  all 
possible, use this unit in the temperature range as indicated in 
the specifications.

When connecting this unit to external devices, be sure to read 

all related operation manuals and connect the devices correctly 
to each other. If there are mistakes in the connections, it is pos-
sible that either the KS-6001 or the other unit(s) will be dam-
aged. 
In the event that smoke or odors come from the unit, turn off 
the power and remove all batteries and external power supply 
sources at once. Contact your dealer or service representative. 
In the event of damage or injury caused by accidents, improper 
operation or functioning, the proper course of action shall be 
determined  according  to  our  service  regulations.  Please  note 
that we cannot be responsible in any way for any loss of pre-re-
corded material.

Содержание KS-6001

Страница 1: ...POWER PEAK PEAK PEAK PEAK FD LINK FD LINK 0 0 2 L F P R L C 0 0 2 70 30 20 4 L F P R L C 0 0 2 L F P R L C 0 0 2 L F P R L C LINE Dy M P 48 A B 70 30 20 4 70 30 20 4 70 30 20 4 LINE Dy M P 48 A B LIN...

Страница 2: ......

Страница 3: ...ed under different conditions there is a risk of fire damage to the unit or personal injury Note the following with regard to external power supplies Make sure the polarity of the external powering de...

Страница 4: ...e are mistakes in the connections it is pos sible that either the KS 6001 or the other unit s will be dam aged In the event that smoke or odors come from the unit turn off the power and remove all bat...

Страница 5: ...ecessed again by sliding the release lever and pressing down the connector until it locks at the recessed posi tion Connector cover if the KS 6001 is being used as a stand alone unit you should always...

Страница 6: ...type of carrying case make sure that all units are firmly affixed in the appropriate specially designed carrying case In the event of a major shock to the unit there is a risk of damage to the connec...

Страница 7: ...e connectors supplied or approved by Kamesan in the event of any doubt please contact Kamesan or an appointed distributor directly Mix switch The three position switch is useful when using the KS 6001...

Страница 8: ...0 0 2 L F P R L C 0 0 2 L F P R L C LINE Dy M P 48 A B 70 30 20 4 70 30 20 4 70 30 20 4 LINE Dy M P 48 A B LINE Dy M P 48 A B LINE Dy M P 48 A B LCF PFL switch Use this control to sweep the low cut fi...

Страница 9: ...l Input trim control Used to adjust the level of the signal fed to each channel The amount of trim depends on the input set ting the blue figures indicate line level settings and the white figures ind...

Страница 10: ...There is a risk of serious dam age to equipment if the wrong selection is made Make the multi pin output power connection Turn on the power when the connections have been made The unity gain position...

Страница 11: ...40mA High pass filter 12dB octave sweepable cutoff between 20Hz and 200Hz Outputs Output level 20dBs from a 7 pin Cannon connector electrically balanced low impedance output Maximum output 8dBs into...

Страница 12: ...e KS 342 and KS 6001 used together 2 h manganese cells 3 h alkaline cells 6 h NP 1 pack Battery life KS KS 6001 used as standalone 2 h manganese cells 3 h alkaline cells 6 h NP 1 pack Physical specifi...

Страница 13: ...X BUS PFL TALLY PFL TALLY XLR7 32 L MIX BUS R MIX BUS POWER OUT INPUT INPUT INPUT INPUT EXT I O A B12V MONI OUT L AUX IN R AUX IN 9 16V 9 16V 20dBs XLR 3 XLR 3 XLR 3 XLR 3 EXT I O INS I O MIX OUT EXT...

Страница 14: ...y large heavy equipment ease of use since time is always of the es sence in the environments where our products are used and quality to match the needs that today s broadcasters require Our head offic...

Страница 15: ......

Страница 16: ...Sigma Systems Engineering Co Ltd 3 5 2 Okubo Shinjuku ku Tokyo 169 0072 JAPAN Tel 81 3 3204 2611 Fax 81 3 3204 2250 e mail sales kamesan co jp...

Отзывы: