9
OIDMANUAL 1219
KAM CONTROLS, INC.
I N S TA L L AT I O N C O N T I N U E D
Pull shaft back until the probe is all the way in the seal housing and tighten the Socket Cap Screws on the locking
collar. This will prevent the OID™ shaft from sliding and the probe from getting damaged during mounting.
Measure the distance (D1) from the outside diameter of main pipe to the end of the connection where the OID™
sensor is going to be installed. FIG. 3-5.
D1
D1
Calculate the insertion distance for
Flanged Seal Housing
(If you have a MNPT Seal Housing, proceed to
step 9):
Total Insertion Distance (TID) = D1 + Pipe Wall Thi Seal Thickness -1/4"
Example for D1= 19", Pipe WT=3/8", and Seal Thickness is 1/8"
TID=19 + 3/8 + 1/8 – 1/4 or TID=19 + .375 + .125 – .25
TID= 19 1/4" or 19.25"
7.
5.
6.
FIG. 3-5
Use the calculated TID and mark a second line on the shaft, measuring from first mark. FIG. 3-6.
8.
9.
Bolt or screw the OID™ sensor to the valve or designated installation location.
(KAM CONTROLS recommends using thread sealant and not Teflon tape for the threaded OID™). Skip to Step 12
(OID with Flanged Seal Housing only).
First Mark
Second Mark
FIG. 3-6
TID